A comparison of two laser-based methods for determination of burn scar perfusion: Laser Doppler versus laser speckle imaging

被引:126
作者
Stewart, CJ [1 ]
Frank, R [1 ]
Forrester, KR [1 ]
Tulip, J [1 ]
Lindsay, R [1 ]
Bray, RC [1 ]
机构
[1] Univ Calgary, Dept Surg, McCaig Ctr Joint Injury & Arthrit Res, Calgary, AB T2N 4N1, Canada
基金
加拿大健康研究院;
关键词
laser Doppler perfusion imaging; laser speckle perfusion imaging; Vancouver burn scar scale;
D O I
10.1016/j.burns.2005.04.004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Laser Doppler perfusion imaging (LDI) is an established technique for early assessment of burn depth to help determine a course of treatment. Laser speckle perfusion imaging (LSPI) is an alternative laser based, non-invasive perfusion monitoring technique that offers rapid and high resolution images of tissue. We have evaluated the ability of the LSPI instrument in determining and monitoring burn scar perfusion over time and compared it with the LDI instrument as a standard. Methods: Ten patients with hypertrophic burn scars (time since injury: 1-8 months) were recruited. Burn scars were scanned with both instruments (LSPI and LDI) monthly over a period of 11 months. Clinical grading of the burn scars was assessed on every scan date using the Vancouver burn scar scale. Results: Comparison of the perfusion values determined by each instrument shows a strong positive correlation, r(2) = 0.86 (n = 63). Each instrument's output also correlated significantly with the clinical gading of the scar, indicating the expected decrease in perfusion as the clinical condition of the scars improved with time. Significance: The new LSPI instrument compared favorably with the established LDI instrument, yielding similar results. The considerably faster scan time and higher resolution of the LSPI method provides a distinct clinical advantage, both in terms of patient comfort and for reliably matching perfusion characteristics to their associated anatomical features. The fast temporal response of the LSPI instrument could be used to monitor near real-time responses to mechanical or pharmacological interventions to study dynamic vascular changes to burn damaged tissues. (c) 2005 Elsevier Ltd and ISBI. All rights reserved.
引用
收藏
页码:744 / 752
页数:9
相关论文
共 41 条
  • [1] MULTISPECTRAL IMAGING OF BURN WOUNDS - A NEW CLINICAL INSTRUMENT FOR EVALUATING BURN DEPTH
    AFROMOWITZ, MA
    CALLIS, JB
    HEIMBACH, DM
    DESOTO, LA
    NORTON, MK
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (10) : 842 - 850
  • [2] Atiles L., 1995, Journal of Burn Care and Rehabilitation, V16, P388, DOI 10.1097/00004630-199507000-00003
  • [3] BENNETT J E, 1957, Plast Reconstr Surg (1946), V20, P261, DOI 10.1097/00006534-195710000-00001
  • [4] Black K S, 1986, J Burn Care Rehabil, V7, P313, DOI 10.1097/00004630-198607000-00003
  • [5] INVIVO MICRO-CIRCULATION OF A SCALD BURN AND THE PROGRESSION OF POST-BURN DERMAL ISCHEMIA
    BOYKIN, JV
    ERIKSSON, E
    PITTMAN, RN
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1980, 66 (02) : 191 - 198
  • [6] Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits
    Bray, R
    Forrester, K
    McDougall, JJ
    Damji, A
    Ferrell, WR
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (03) : 227 - 231
  • [7] Laser Doppler imaging of burn scars: a comparison of wavelength and scanning methods
    Bray, R
    Forrester, K
    Leonard, C
    McArthur, R
    Tulip, J
    Lindsay, R
    [J]. BURNS, 2003, 29 (03) : 199 - 206
  • [8] BRIERS JD, 1982, INVEST OPHTH VIS SCI, V22, P255
  • [9] QUASI REAL-TIME DIGITAL VERSION OF SINGLE-EXPOSURE SPECKLE PHOTOGRAPHY FOR FULL-FIELD MONITORING OF VELOCITY OR FLOW-FIELDS
    BRIERS, JD
    WEBSTER, S
    [J]. OPTICS COMMUNICATIONS, 1995, 116 (1-3) : 36 - 42
  • [10] Capillary blood flow monitoring using laser speckle contrast analysis (LASCA)
    Briers, JD
    Richards, G
    He, XW
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) : 164 - 175