Coronary MR angiography: Comparison of quantitative and qualitative data from four techniques

被引:39
作者
Maintz, D
Aepfelbacher, FC
Kissinger, KV
Botnar, RM
Danias, PG
Heindel, W
Manning, WJ
Stuber, M
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Med & Radiol,Cardiovasc Div, Boston, MA 02115 USA
[2] Philips Med Syst, Best, Netherlands
关键词
D O I
10.2214/ajr.182.2.1820515
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS. Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7+/-5.7 and 15.2+/-3.9) and balanced fast field-echo (23.5+/-1.7 and 14.4+/-8.1) sequences compared with the turbo field-echo (12.5+/-2.7 and 8.3+/-2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6+/-0.5 mm) than with the other techniques (turbo field-echo, 3.0+/-0.5 torn, p = 0.6; balanced fast field-echo, 3.1+/-0.5 mm, p < 0.01; fast spin-echo, 3.1+/-0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6%+/-8.5% compared with turbo field-echo, 44.0%+/-6.6%; spiral, 44.7%+/-6.5%; fast spin-echo, 18.4%+/-6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5+/-0.6 min), and for the spiral acquisitions was shortest (5.2+/-0.3 min). CONCLUSION. Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.
引用
收藏
页码:515 / 521
页数:7
相关论文
共 24 条
  • [1] *AM HEART ASS, 2001, HEART STROK STAT UPD
  • [2] Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography
    Börnert, P
    Stuber, M
    Botnar, RM
    Kissinger, KV
    Koken, P
    Spuentrup, E
    Manning, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 789 - 794
  • [3] Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    Botnar, RM
    Stuber, M
    Danias, PG
    Kissinger, KV
    Manning, WJ
    [J]. CIRCULATION, 1999, 99 (24) : 3139 - 3148
  • [4] CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST
    BRITTAIN, JH
    HU, BS
    WRIGHT, GA
    MEYER, CH
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 689 - 696
  • [5] FAST ALGORITHMS FOR LOW-LEVEL VISION
    DERICHE, R
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (01) : 78 - 87
  • [6] Breath-hold three-dimensional true-FISP imaging of coronary arteries using asymmetric sampling
    Deshpande, VS
    Shea, SM
    Chung, YC
    McCarthy, RM
    Finn, JP
    Li, DB
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 473 - 478
  • [7] 3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries
    Deshpande, VS
    Shea, SM
    Laub, G
    Simonetti, OP
    Finn, JP
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 494 - 502
  • [8] FAST SELECTIVE BLACK BLOOD MR IMAGING
    EDELMAN, RR
    CHIEN, D
    KIM, D
    [J]. RADIOLOGY, 1991, 181 (03) : 655 - 660
  • [9] Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms
    Etienne, A
    Botnar, RM
    van Muiswinkel, AMC
    Boesiger, P
    Manning, WJ
    Stuber, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 658 - 666
  • [10] FAST 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING
    IRARRAZABAL, P
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 656 - 662