MR venography of the human brain using susceptibility weighted imaging at very high field strength

被引:95
作者
Koopmans, Peter J. [1 ]
Manniesing, Rashindra [2 ]
Niessen, Wiro J. [2 ]
Viergever, Max A. [3 ]
Barth, Markus [1 ,4 ]
机构
[1] Radboud Univ Nijmegen, FC Donders Ctr Cognit Neuroimaging, NL-6500 HB Nijmegen, Netherlands
[2] Dept Med Informat & Radiol, Rotterdam, Netherlands
[3] Univ Med Ctr, Image Sci Inst, Utrecht, Netherlands
[4] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
关键词
neuroimaging; venography; 3; T; 7; parallel imaging; vessel segmentation; vessel enhancing diffusion; transverse relaxation times;
D O I
10.1007/s10334-007-0101-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective We investigate the implications of high magnetic field strength on MR venography based on susceptibility-weighted imaging (SWI) and estimate the optimum echo time to obtain maximum contrast between blood and brain tissue. Materials and methods We measured tissue contrast and T*(2) relaxation times at 7 T of gray matter, white matter, and venous blood in vivo. Results T*(2) relaxation times of gray matter, white matter, and venous blood in vivo yielded 32.9 +/- 2.3, 27.7 +/- 4.3, and 7.4 +/- 1.4 ms, respectively. Optimum TE was found to be 15 ms which is supported by theoretical considerations. Using this optimum TE, we acquired 3D high resolution datasets with a large volume coverage in a short measurement time that show very detailed microanatomical structures of the human brain such as intracortical veins and laminar cortical substructures. Conclusions By applying optimised vessel filters (vesselness filter and vessel enhancing diffusion) whole brain MR venograms can be obtained at 7 T with a significantly reduced measurement time compared to 3 T.
引用
收藏
页码:149 / 158
页数:10
相关论文
共 44 条
[1]   Very high-resolution three-dimensional functional MRI of the human visual cortex with elimination of large venous vessels [J].
Barth, M. ;
Norris, D. G. .
NMR IN BIOMEDICINE, 2007, 20 (05) :477-484
[2]   High-resolution three-dimensional contrast-enhanced blood oxygenation level-dependent magnetic resonance venography of brain tumors at 3 Tesla:: First clinical experience and comparison with 1.5 Tesla [J].
Barth, M ;
Nöbauer-Huhmann, IM ;
Reichenbach, JR ;
Mlynárik, V ;
Schöggl, A ;
Matula, C ;
Trattnig, S .
INVESTIGATIVE RADIOLOGY, 2003, 38 (07) :409-414
[3]  
Barth M, 1997, CELL MOL BIOL, V43, P783
[4]  
BLOCKLEY NP, 2006, P ISMRM SEATTL, P2516
[5]   In vivo micro-MRI of intracortical neurovasculature [J].
Bolan, Patrick J. ;
Yacoub, Essa ;
Garwood, Michael ;
Ugurbil, Kamil ;
Harel, Noam .
NEUROIMAGE, 2006, 32 (01) :62-69
[6]   MR GRADIENT-ECHO IMAGING OF INTRAVASCULAR BLOOD OXYGENATION - T-2(ASTERISK) DETERMINATION IN THE PRESENCE OF FLOW [J].
CHIEN, D ;
LEVIN, DL ;
ANDERSON, CM .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (04) :540-545
[7]  
DEISTUNG A, 2006, P ISMRM ISMRM SEATTL, P1948
[8]   High-field MRI of brain cortical substructure based on signal phase [J].
Duyn, Jeff H. ;
van Gelderen, Peter ;
Li, Tie-Qiang ;
de Zwart, Jacco A. ;
Koretsky, Alan P. ;
Fukunaga, Masaki .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (28) :11796-11801
[9]  
Frangi AF, 1998, LECT NOTES COMPUT SC, V1496, P130, DOI 10.1007/BFb0056195
[10]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210