Simultaneous derivatization and extraction of amphetamine-like drugs in urine with headspace solid-phase microextraction followed by gas chromatography-mass spectrometry

被引:37
作者
Chia, KJ [1 ]
Huang, SD [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 30043, Taiwan
关键词
solid-phase microextraction; derivatization; amphetamine; urine;
D O I
10.1016/j.aca.2005.03.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and solvent-free procedure for the determination of amphetamine-like drugs, amphetamine (AM), methamphetamine (MeAM), methylen-dioxyamphetamine (MDA), methylen-dioxymethamphetamine (MDMA) and methylen-dioxyethylamphetamine (MDEA) in urine samples was developed using solid-phase microextraction (SPME) with an on-fiber derivatization device. In this study, the amphetamine-like drugs were derivatized with heptafluorobutyric anhydride (HFBA) and heptafluorobutyric chloride (HFBCI) and determined by means of a gas chromatography-mass spectrometer with selected ion storage (SIS) detection. An improved design was used for sample preparation. The test specimen was placed in an 8 ml vial along with additives (KOH and NaCI), a glass insert with twelve holes containing the derivatizing reagents was inserted into the vial, and the vial was then sealed tightly. A SPME device with a 100 mu m polydimethylsiloxane fiber was inserted into the vial and the fiber was exposed to the headspace in the insert, then the vial was heated and stirred at 95 degrees C and 600 rpm for 30 min for evaporation/adsorption/derivatization. The SPME needle was finally removed and inserted into the GC injection port to desorb the analytes. The influence of several parameters on the efficiency of microextraction (type of fiber coating, extraction time, extraction temperature, etc.) was investigated. The SPME method developed provides good sensitivity with a calibration range from 0.5 to 1000 ng ml(-1) for MDA, and 0.1-1000 ng ml(-1) for AM, MA, MDMA and MDEA. The method detection limits (MDLs) are in the range 0.016-0.193 ng ml(-1) with the studied drugs. This method was also successfully tested on real samples of urine from people who were suspected of using amphetamines. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 23 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]  
ARTHUR CL, 1992, ENVIRON SCI TECHNOL, V26, P279
[3]   Simultaneous detection of some drugs of abuse in saliva samples by SPME technique [J].
Fucci, N ;
De Giovanni, N ;
Chiarotti, M .
FORENSIC SCIENCE INTERNATIONAL, 2003, 134 (01) :40-45
[4]   Rapid screening procedure based on headspace solid-phase microextraction and gas chromatography-mass spectrometry for the detection of many recreational drugs in hair [J].
Gentili, S ;
Cornetta, M ;
Macchia, T .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 801 (02) :289-296
[5]   One step and highly sensitive headspace solid-phase microextraction sample preparation approach for the analysis of methamphetamine and amphetamine in human urine [J].
Huang, MK ;
Liu, CR ;
Huang, SD .
ANALYST, 2002, 127 (09) :1203-1206
[6]   Rapid analysis of amphetamine, methamphetamine, MDA, and MDMA in urine using solid-phase microextraction, direct on-fiber derivatization, and analysis by GC-MS [J].
Jurado, C ;
Giménez, MP ;
Soriano, T ;
Menéndez, M ;
Repetto, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (01) :11-16
[7]   Single-step procedure for gas chromatography-mass spectrometry screening and quantitative determination of amphetamine-type stimulants and related drugs in blood, serum, oral fluid and urine samples [J].
Kankaanpää, A ;
Gunnar, T ;
Ariniemi, K ;
Lillsunde, P ;
Mykkänen, S ;
Seppälä, T .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (01) :57-68
[8]   Optimization of headspace solid-phase microextraction conditions for the determination of organophosphorus insecticides in natural waters [J].
Lambropoulou, DA ;
Albanis, TA .
JOURNAL OF CHROMATOGRAPHY A, 2001, 922 (1-2) :243-255
[9]   Microextraction of drugs [J].
Lord, H ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :17-63
[10]  
NAGASAWA N, 2000, FORENSIC SCI INT, V109, P215