Novel steerable telescoping catheter system for implantation of left ventricular pacing leads

被引:7
作者
Geske, JB
Goldstein, RN
Stambler, BS
机构
[1] Case Western Reserve Univ, Univ Hosp Cleveland, Cleveland, OH 44106 USA
[2] Medtronic Inc, Mayo Med Sch, Minneapolis, MN USA
关键词
congestive heart failure; biventricular pacing; cardiac resynchronization therapy; coronary sinus;
D O I
10.1007/s10840-005-5845-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Advances in left ventricular transvenous lead delivery systems for biventricular pacing are leading to more refined techniques, shorter procedure times and higher implant success rates. Despite these advances, the inability to successfully cannulate the coronary sinus and deliver a lead to a distal location are still major causes of prolonged procedures times and implant failures. The pathophysiologic process of heart failure results in dilatation of the right atrium as well as other morphological changes in cardiac anatomy. Additionally, cannulation can be further complicated by congenital anomalous cardiac anatomy. This report describes the implant of a biventricular pacing system using a novel, steerable 7 French catheter system developed to aid in the cannulation of the coronary sinus ostium and its venous branches. The steerable catheter is used in conjunction with a 9 French braided sheath and guide-wire to create a telescoping system. The use of new tools and methods as described provides insight into available options for left ventricular transvenous lead implantation and dealing with difficult anatomy.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 18 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]   A method for permanent transvenous left ventricular pacing [J].
Blanc, JJ ;
Benditt, DG ;
Gilard, M ;
Etienne, Y ;
Mansourati, J ;
Lurie, KG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2021-2024
[3]   Comparative prospective randomized efficacy testing of different guiding catheters for coronary sinus cannulation in heart failure patients [J].
Butter, C ;
Gras, D ;
Ritter, P ;
Stellbrink, C ;
Fleck, E ;
Tockman, B ;
Schubert, B ;
Pochet, T ;
deVoogt, W .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2003, 9 (03) :343-351
[4]   Effect of resynchronization therapy stimulation site on the systolic function of heart failure patients [J].
Butter, C ;
Auricchio, A ;
Stellbrink, C ;
Fleck, E ;
Ding, J ;
Yu, YH ;
Huvelle, E ;
Spinelli, J .
CIRCULATION, 2001, 104 (25) :3026-3029
[5]   A randomized comparison of alternative techniques to achieve coronary sinus cannulation during biventricular implantation procedures [J].
De Martino, G ;
Sanna, T ;
Dello Russo, A ;
Pelargonio, G ;
Messano, L ;
Ierardi, C ;
Gabrielli, D ;
Parisi, Q ;
Zecchi, P ;
Bellocci, F ;
Crea, F .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 10 (03) :227-230
[6]   FUNCTIONAL ABNORMALITIES IN ISOLATED LEFT-BUNDLE BRANCH-BLOCK - THE EFFECT OF INTERVENTRICULAR ASYNCHRONY [J].
GRINES, CL ;
BASHORE, TM ;
BOUDOULAS, H ;
OLSON, S ;
SHAFER, P ;
WOOLEY, CF .
CIRCULATION, 1989, 79 (04) :845-853
[7]   QRS duration and mortality in patients with congestive heart failure [J].
Iuliano, S ;
Fisher, SG ;
Karasik, PE ;
Fletcher, RD ;
Singh, SN .
AMERICAN HEART JOURNAL, 2002, 143 (06) :1085-1091
[8]  
Kocovic D, 2002, J AM COLL CARDIOL, V39, p77A
[9]   A pilot experience with permanent biventricular pacing to treat advanced heart failure [J].
Leclercq, C ;
Cazeau, S ;
Ritter, P ;
Alonso, C ;
Gras, D ;
Mabo, P ;
Lazarus, A ;
Daubert, JC .
AMERICAN HEART JOURNAL, 2000, 140 (06) :862-870
[10]  
Leon Angel R, 2003, Rev Cardiovasc Med, V4, P142