Kinematic analysis of kneeling in cruciate-retaining and posterior-stabilized total knee arthroplasties

被引:42
作者
Hamai, Satoshi [1 ]
Miura, Hiromasa [1 ]
Higaki, Hidehiko [2 ]
Matsuda, Shuichi [1 ]
Shimoto, Takeshi [2 ]
Sasaki, Kousuke [1 ]
Yoshizumi, Masaaki [2 ]
Okazaki, Ken [1 ]
Tsukamoto, Nobuaki [1 ]
Iwamoto, Yukihide [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Sangyo Univ, Fac Engn, Dept Mech Engn, Fukuoka 8138583, Japan
关键词
kinematics; kneeling; posterior cruciate ligament; post-cam mechanism; total knee arthroplasty;
D O I
10.1002/jor.20512
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Kneeling is an important function of the knee for many activities of daily living. In this study, we evaluated the in vivo kinematics of kneeling after total knee arthroplasty (TKA) using radiographic based image-matching techniques. Kneeling from 90 to 120 degrees of knee flexion produced a posterior femoral rollback after both cruciate-retaining and posterior-stabilized TKA. It could be assumed that the posterior cruciate ligament and the post-cam mechanism were functioning. The posterior-stabilized TKA design had contact regions located far posterior on the tibial insert in comparison to the cruciate-retaining TKA. Specifically, the lateral femoral condyle in posterior-stabilized TKA translated to the posterior edge of the tibial surface, although there was no finding of subluxation. After posterior-stabilized TKA, the contact position of the post-cam translated to the posterior medial corner of the post with external rotation of the femoral component. Because edge loading can induce accelerated polyethylene wear, the configuration of the post-cam mechanism should be designed to provide a larger contact area when the femoral component rotates. (c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:435 / 442
页数:8
相关论文
共 37 条
[1]
Andriacchi T P, 1988, J Arthroplasty, V3 Suppl, pS13, DOI 10.1016/S0883-5403(88)80003-2
[2]
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[3]
A LATERAL SKIN INCISION REDUCES PERIPATELLAR DYSAESTHESIA AFTER KNEE SURGERY [J].
BERG, P ;
MJOBERG, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (03) :374-376
[4]
In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty [J].
Bertin, KC ;
Komistek, RD ;
Dennis, DA ;
Hoff, WA ;
Anderson, DT ;
Langer, T .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1040-1048
[5]
Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm [J].
Browne, C ;
Hermida, JC ;
Bergula, A ;
Colwell, CW ;
D'Lima, DD .
KNEE, 2005, 12 (02) :81-88
[6]
The influence of femoral rollback on patellofemoral contact loads in total knee arthroplasty [J].
Churchill, DL ;
Incavo, SJ ;
Johnson, CC ;
Beynnon, BD .
JOURNAL OF ARTHROPLASTY, 2001, 16 (07) :909-918
[7]
Polyethylene post failure in posterior stabilized total knee arthroplasty [J].
Clarke, HD ;
Math, KR ;
Scuderi, GR .
JOURNAL OF ARTHROPLASTY, 2004, 19 (05) :652-657
[8]
Dahlkvist N J, 1982, Eng Med, V11, P69, DOI 10.1243/EMED_JOUR_1982_011_019_02
[9]
Fukuoka Y, 1999, IEEE Trans Rehabil Eng, V7, P228, DOI 10.1109/86.769413
[10]
Marker Configuration Model-Based Roentgen Fluoroscopic Analysis [J].
Garling, EH ;
Kaptein, BL ;
Geleijns, K ;
Nelissen, RGHH ;
Valstar, ER .
JOURNAL OF BIOMECHANICS, 2005, 38 (04) :893-901