Marker Configuration Model-Based Roentgen Fluoroscopic Analysis

被引:59
作者
Garling, EH
Kaptein, BL
Geleijns, K
Nelissen, RGHH
Valstar, ER
机构
[1] Leiden Univ, Med Ctr, Dept Orthopaed, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
[3] Delft Univ Technol, Fac Sci Appl, Dept Image Sci & Technol, Quantitat Imaging Grp, NL-2600 AA Delft, Netherlands
关键词
kinematics; mobile bearing; fluoroscopy; computer simulation; image processing;
D O I
10.1016/j.jbiomech.2004.04.026
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
It remains unknown if and how the polyethylene bearing in mobile bearing knees moves during dynamic activities with respect to the tibial base plate. Marker Configuration Model-Based Roentgen Fluoroscopic Analysis (MCM-based RFA) uses a marker configuration model of inserted tantalum markers in order to accurately estimate the pose of an implant or bone using single plane Roentgen images or fluoroscopic images. The goal of this study is to assess the accuracy of (MCM-Based RFA) in a standard fluoroscopic set-up using phantom experiments and to determine the error propagation with computer simulations. The experimental set-up of the phantom study was calibrated using a calibration box equipped with 600 tantalum markers, which corrected for image distortion and determined the focus position. In the computer simulation study the influence of image distortion, MC-model accuracy, focus position, the relative distance between MC-models and MC-model configuration on the accuracy of MCM-Based RFA were assessed. The phantom study established that the in-plane accuracy of MCM-Based RFA is 0.1 mm and the out-of-plane accuracy is 0.9 mm. The rotational accuracy is 0.1 degrees. A ninth-order polynomial model was used to correct for image distortion. Marker-Based RFA was estimated to have, in a worst case scenario, an in vivo translational accuracy of 0.14mm (x-axis), 0.17mm (y-axis), 1.9mm (z-axis), respectively, and a rotational accuracy of 0.3 degrees. When using fluoroscopy to study kinematics, image distortion and the accuracy of models are important factors, which influence the accuracy of the measurements. MCM-Based RFA has the potential to be an accurate, clinically useful tool for studying kinematics after total joint replacement using standard equipment. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:893 / 901
页数:9
相关论文
共 29 条
[1]   Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[2]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[3]   The precision of radiostereometric measurements.: Manual vs. digital measurements [J].
Börlin, N ;
Thien, T ;
Kärrholm, J .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :69-79
[4]  
Callaghan J J, 2001, Instr Course Lect, V50, P431
[5]   Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions [J].
Dennis, DA ;
Komistek, RD ;
Stiehl, JB ;
Walker, SA ;
Dennis, KN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :748-752
[6]  
DENNIS DA, 1996, CLIN ORTHOP RELAT R, V331, P107
[7]  
Duda R. O., 1973, PATTERN CLASSIFICATI
[8]   A global method based on thin-plate splines for correction of geometric distortion: An application to fluoroscopic images [J].
Fantozzi, S ;
Cappello, A ;
Leardini, A .
MEDICAL PHYSICS, 2003, 30 (02) :124-131
[9]  
Fukuoka Y, 1999, IEEE Trans Rehabil Eng, V7, P228, DOI 10.1109/86.769413
[10]   Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy [J].
Hoff, WA ;
Komistek, RD ;
Dennis, DA ;
Gabriel, SM ;
Walker, SA .
CLINICAL BIOMECHANICS, 1998, 13 (07) :455-472