Atomization of Al in a tungsten coil electrothermal atomic absorption spectrophotometer

被引:31
作者
Luccas, PO
Nóbrega, JA
Oliveira, PV
Krug, FJ
机构
[1] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
electrothermal atomic absorption spectrophotometry; spectrophotometry; tungsten coil atomizer; aluminum; hemodialysis solution;
D O I
10.1016/S0039-9140(98)00294-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrothermal atomic absorption spectrophotometry of Al in a tungsten coil atomizer was evaluated and applied for its determination in hemodialysis fluid. The system was mounted on a Varian Spectra AA-40 spectrophotometer with continuum background correction and all measurements, in peak height absorbance, were done at 309.3 nm. The purge gas was a mixture of 90% Ar plus 10% H-2. Observation height, gas flow, drying, pyrolysis and atomization steps were optimized. The heating program was carried out by employing a heating cycle in four steps: dry, pyrolysis, atomization and clean. The determination of Al in hemodialysis solutions was performed by using a matrix-matching procedure. Al in hemodialysis solutions was determined by TCA and by electrothermal atomization with a graphite tube atomizer. There is no differences between results obtained by both methods at a confidence level of 95%. The characteristic mass of Al by using the TCA was 39 pg and the detection limit was 2.0 mu g l(-1). (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:695 / 703
页数:9
相关论文
共 36 条
[1]  
ACETO M, 1994, ATOM SPECTROSC, V15, P237
[2]   SIMPLE LOW-COST TUNGSTEN-COIL ATOMIZER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BERNDT, H ;
SCHALDACH, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :709-712
[3]   ANALYTICAL EVALUATION OF A TUNGSTEN COIL ATOMIZER FOR CADMIUM, LEAD, CHROMIUM, MANGANESE, NICKEL AND COBALT DETERMINATION BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BRUHN, CG ;
AMBIADO, FE ;
CID, HJ ;
WOERNER, R ;
TAPIA, J ;
GARCIA, R .
ANALYTICA CHIMICA ACTA, 1995, 306 (2-3) :183-192
[4]  
Bruhn CG, 1996, QUIM ANAL, V15, P191
[5]   VOLTAMMETRIC DETERMINATION OF ALUMINUM IN HEMODIALYSIS CONCENTRATES USING THE ADSORPTION OF THE AL(III)-1,2-DIHYDROXYANTRAQUINONE-3-SULFONIC ACID COMPLEX IN PRESENCE OF CALCIUM [J].
CARRERA, ME ;
RODRIGUEZ, V ;
TORAL, MI ;
RICHTER, P .
ANALYTICAL LETTERS, 1993, 26 (12) :2575-2585
[6]  
DRAIBE S, 1994, CIENCIA HOJE, V18, P42
[7]  
ERICSON S, 1993, AA109 VARI INSTR WOR
[8]  
GAYON JM, 1992, J ANAL ATOM SPECTROM, V7, P742
[9]   DETERMINATION OF CADMIUM IN BIOLOGICAL-MATERIALS BY TUNGSTEN COIL ATOMIC-ABSORPTION SPECTROMETRY [J].
GINE, MF ;
KRUG, FJ ;
SASS, VA ;
REIS, BF ;
NOBREGA, JA ;
BERNDT, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :243-245
[10]   IMPROVED ET-AAS DETERMINATION OF ALKALINE AND EARTH ALKALINE ELEMENTS WITH A SIMPLE LOW-COST TUNGSTEN COIL ATOMIZER [J].
HAVESOV, I ;
IVANOVA, E ;
BERNDT, H ;
SCHALDACH, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (06) :484-485