Comparison of gastric emptying of a nondigestible capsule to a radio-labelled meal in healthy and gastroparetic subjects

被引:233
作者
Kuo, B. [1 ]
McCallum, R. W. [2 ]
Koch, K. L. [3 ]
Sitrin, M. D. [4 ]
Wo, J. M. [5 ]
Chey, W. D. [6 ]
Hasler, W. L. [6 ]
Lackner, J. M. [7 ]
Katzt, L. A. [8 ]
Semler, J. R. [9 ]
Wilding, G. E. [10 ]
Parkman, H. P. [11 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Gastroenterol Unit, Boston, MA USA
[2] Univ Kansas, Ctr Med, Ctr Gastrointestinal Nerve & Muscle Func & GI Mot, Kansas City, KS USA
[3] Wake Forest Univ, Baptist Med Ctr, Gastroenterol Sect, Winston Salem, NC 27109 USA
[4] SUNY Buffalo, Western New York VA Med Ctr, Dept Med, Div Gastroenterol & Hepatol, Buffalo, NY 14260 USA
[5] Univ Louisville, Div Gastroenterol & Hepatol, Louisville, KY 40292 USA
[6] Univ Michigan, Dept Internal Med, Div Gastroenterol, Ann Arbor, MI 48109 USA
[7] SUNY Buffalo, Sch Med, Dept Med Behav Med Clin, Div Gastroenterol Hepatol & Nutr, Buffalo, NY 14260 USA
[8] SUNY Buffalo, Sch Med, Dept Med, Buffalo, NY 14260 USA
[9] SmartPill Corp, Buffalo, NY USA
[10] SUNY Buffalo, Dept Biostat, Buffalo, NY 14260 USA
[11] Temple Univ, Sch Med, Dept Med, Gastroenterol Sect, Philadelphia, PA 19122 USA
关键词
D O I
10.1111/j.1365-2036.2007.03564.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Gastric emptying scintigraphy (GES) using a radio-labelled meal is used to measure gastric emptying. A nondigestible capsule, SmartPill, records luminal pH, temperature, and pressure during gastrointestinal transit providing a measure of gastric emptying time (GET). Aims To compare gastric emptying time and GES by assessing their correlation, and to compare GET and GES for discriminating healthy subjects from gastroparetics. Methods Eighty-seven healthy subjects and 61 gastroparetics enrolled with Fasted subjects were ingested capsule simultaneous SmartPill and GES. and [Tc-99m]-SC radio-labelled meal. Images were obtained every 30 min for 6 h. Gastric emptying time and percentage of meal remaining at 2/4 h were determined for each subject. The sensitivity/specificity and receiver operating characteristic analysis of each measure were determined for each subject. Results Correlation between GET and GES-4 h was 0.73 and GES-2 h was 0.63. The diagnostic accuracy from the receiver operating characteristic curve between gastroparetics and healthy subjects was GET = 0.83, GES-4 h = 0.82 and GES-2 h = 0.79. The 300-min cut-off time for GET gives sensitivity of 0.65 and specificity of 0.87 for diagnosis of gastroparesis. The corresponding sensitivity/specificity for 2 and 4 h standard GES measures were 0.34/0.93 and 0.44/0.93, respectively. Conclusion SmartPill GET correlates with GES and discriminates between healthy and gastroparetic subjects offering a nonradioactive, standardized, ambulatory alternative to scintigraphy.
引用
收藏
页码:186 / 196
页数:11
相关论文
共 18 条
[1]
[Anonymous], 2003, Techniques for censored and truncated data, DOI DOI 10.1007/0-387-21645-6_3
[2]
CASSILLY DW, 2007, GASTROENTEROLOGY S2, V132, pA97
[3]
[C-13]octanoic acid breath test for gastric emptying of solids: Accuracy, reproducibility, and comparison with scintigraphy [J].
Choi, MG ;
Camilleri, M ;
Burton, DD ;
Zinsmeister, AR ;
Forstrom, LA ;
Nair, KS .
GASTROENTEROLOGY, 1997, 112 (04) :1155-1162
[4]
Performance characteristics of scintigraphic transit measurements for studies of experimental therapies [J].
Cremonini, F ;
Mullan, BP ;
Camilleri, M ;
Burton, DD ;
Rank, MR .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2002, 16 (10) :1781-1790
[5]
MEASUREMENT OF GASTROINTESTINAL PH PROFILES IN NORMAL AMBULANT HUMAN-SUBJECTS [J].
EVANS, DF ;
PYE, G ;
BRAMLEY, R ;
CLARK, AG ;
DYSON, TJ ;
HARDCASTLE, JD .
GUT, 1988, 29 (08) :1035-1041
[6]
FAEGENBURG D, 1985, AM J GASTROENTEROL, V80, P787
[7]
FELDMAN M, 1984, GASTROENTEROLOGY, V87, P895
[8]
Video capsule endoscopy (VCE) is useful in the evaluation of unexplained abdominal pain (AP) [J].
Fleischer, DE ;
Leighton, JA ;
Sharma, VK ;
Heigh, RI .
GASTROENTEROLOGY, 2003, 124 (04) :A245-A246
[9]
GORDON SJ, 1987, GASTROENTEROLOGY, V92, P1410
[10]
Yield of repeat wireless video capsule endoscopy in patients with obscure gastrointestinal bleeding [J].
Jones, BH ;
Fleischer, DE ;
Sharma, VK ;
Heigh, RI ;
Shiff, AD ;
Hernandez, JL ;
Leighton, JA .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2005, 100 (05) :1058-1064