Surface-activated chemical ionization ion trap mass spectrometry for the analysis of cocaine and benzoylecgonine in hair after extraction and sample dilution

被引:14
作者
Cristoni, Simone
Basso, Elisa
Gerthoux, Piermario
Mocarelli, Paolo
Gonella, Elisabetta
Brambilla, Maura
Crotti, Sara
Bernardi, Luigi Ross
机构
[1] ISB Source & Biotechnol, I-20138 Milan, Italy
[2] Monzino Cardiol Ctr, Milan, Italy
[3] Bruker Daltonics, Macerata, Italy
[4] Univ Milano Biccoca, Dept Lab Med, Milan, Italy
[5] Desio Hosp, Milan, Italy
[6] Multimed Labs, Milan, Italy
关键词
D O I
10.1002/rcm.3107
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Surface-activated chemical ionization (SACI) was employed for the analysis of cocaine and its metabolite, benzoylecgonine, extracted from hair. Following decontamination and acid hydrolysis procedures on the hair sample, the sample solution was diluted (1:10) and directly analyzed by liquid chromatography/surface-activated chemical ionization multiple collisional stage single reaction monitoring mass spectrometry (LC/SACI-MS3-SRM) without solid-phase extraction (SPE) prepurification and concentration procedures. To increase the selectivity of the method, MS3 was chosen instead of the less selective MS/MS. This data was compared with that achieved using gas chromatography/mass spectrometry (GC/MS), the reference method used by the Italian Government Institute of Health protocol. The limits of detection (LODs) were 0.003 ng/(mg hair) for cocaine and 0.02 ng/(mg hair) for benzoylecgonine and the limits of quantitation (LOQs) were 0.01 ng/(mg hair) for cocaine and 0.04 ng/(mg hair) for benzoylecgonine. The squared correlation coefficient (R-2) of the calibration curve was 0.9887-0.9980 for cocaine and 0.9987-0.9997 for benzoylecgonine. The percent accuracy error was 2-5% for both cocaine and benzoylecgonine using the LC/SACI-MS3-SRM approach, whereas it was higher for benzoylecgonine (20-25%) using the LC/SACI-MS/MS-SRM approach compared with the GC/MS data due to hair matrix contamination. In both cases, high precision was achieved (1-3% precision error), which confirmed the stability of the developed methods. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:2515 / 2523
页数:9
相关论文
共 31 条
[1]   Quantitation of cocaine, benzoylecgonine, cocaethylene, methylecgonine, and norcocaine in human hair by positive ion chemical ionization (PICI) gas chromatography-tandem mass spectrometry [J].
Bourland, JA ;
Hayes, EF ;
Kelly, RC ;
Sweeney, SA ;
Hatab, MM .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (07) :489-495
[2]  
Busch K. L., 1983, TANDEM MASS SPECTROM, P11
[3]   Rapid simultaneous quantification of immunosuppressants in transplant patients by turbulent flow chromatography combined with tandem mass spectrometry [J].
Ceglarek, U ;
Lembcke, J ;
Fiedler, GM ;
Werner, M ;
Witzigmann, H ;
Hauss, JP ;
Thiery, J .
CLINICA CHIMICA ACTA, 2004, 346 (02) :181-190
[4]  
Cirimele V, 1996, BIOMED CHROMATOGR, V10, P179, DOI 10.1002/(SICI)1099-0801(199607)10:4<179::AID-BMC586>3.0.CO
[5]  
2-N
[6]   Validation of a gas chromatography - Ion trap tandem mass spectrometry for simultaneous analyse of cocaine and its metabolites in saliva [J].
Cognard, Emmanuelle ;
Bouchonnet, Stephane ;
Staub, Christian .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) :925-934
[7]   Legal, workplace, and treatment drug testing with alternate biological matrices on a global scale [J].
Cone, EJ .
FORENSIC SCIENCE INTERNATIONAL, 2001, 121 (1-2) :7-15
[8]   Surface-activated chemical ionization ion trap mass spectrometry in the analysis of drugs in dilute urine samples. Part II: analysis of morphine and other street drugs [J].
Cristoni, S ;
Cantu, M ;
Bernardi, LR ;
Gerthoux, P ;
Mocarelli, P ;
Brambilla, M ;
Gonella, E ;
Guidugli, F .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (12) :1609-1617
[9]   Surface-activated no-discharge atmospheric pressure chemical ionization [J].
Cristoni, S ;
Bernardi, LR ;
Biunno, I ;
Tubar, M ;
Guidugli, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (17) :1973-1981
[10]   Surface-activated chemical ionization and high-flow gradient chromatography to reduce matrix effect [J].
Cristoni, Simone ;
Bernardi, Luigi Rossi ;
Gerthoux, Piermario ;
Mocarelli, Paolo ;
Brambilla, Maura ;
Gonella, Elisabetta ;
Guidugli, Federico ;
Cantu, Marco .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (16) :2376-2382