An array immunosensor for simultaneous detection of clinical analytes

被引:221
作者
Rowe, CA
Scruggs, SB
Feldstein, MJ
Golden, JP
Ligler, FS
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
[2] Geoctr Inc, Rockville, MD USA
关键词
D O I
10.1021/ac980798t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorescence-based immunosensor has been developed for simultaneous analysis of multiple samples. A patterned array of recognition elements immobilized on the surface of a planar waveguide is used to "capture" analyte present in samples; bound analyte is then quantified by means of fluorescent detector molecules. Upon excitation of the fluorescent label by a small diode laser, a CCD camera detects the pattern of fluorescent antigen:antibody complexes on the sensor surface. Image analysis software correlates the position of fluorescent signals with the identity of the analyte. This immunosensor was used to detect physiologically relevant concentrations of staphylococcal enterotoxin B (SEB), F1 antigen from Yersinia pestis, and D-dimer, a marker of sepsis and thrombotic disorders, in spiked clinical samples.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 51 条
  • [1] Fiber-optic evanescent wave biosensor for the detection of oligonucleotides
    Abel, AP
    Weller, MG
    Duveneck, GL
    Ehrat, M
    Widmer, HM
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (17) : 2905 - 2912
  • [2] BAKALTCHEVA IB, 1998, ACTUATORS B
  • [3] BERRY PR, 1987, SOC APPLIED BACTERIO, V24, P245
  • [4] USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES
    BHATIA, SK
    SHRIVERLAKE, LC
    PRIOR, KJ
    GEORGER, JH
    CALVERT, JM
    BREDEHORST, R
    LIGLER, FS
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) : 408 - 413
  • [5] Step-and-repeat photopatterning of protein features using caged/biotin-BSA: Characterization and resolution
    Blawas, AS
    Oliver, TF
    Pirrung, MC
    Reichert, WM
    [J]. LANGMUIR, 1998, 14 (15) : 4243 - 4250
  • [6] FIBER OPTIC EVANESCENT WAVE IMMUNOSENSORS FOR MEDICAL DIAGNOSTICS
    BLUESTEIN, BI
    WALCZAK, IM
    CHEN, SY
    [J]. TRENDS IN BIOTECHNOLOGY, 1990, 8 (06) : 161 - 168
  • [7] BOCK D, 1995, P SPIE INT SOC OPT E, V2629, P96
  • [8] APPLICATION OF A BEDSIDE WHOLE-BLOOD D-DIMER ASSAY IN THE DIAGNOSIS OF DEEP-VEIN THROMBOSIS
    BRENNER, B
    PERY, M
    LANIR, N
    JABAREEN, A
    MARKEL, A
    KAFTORI, JK
    GAITINI, D
    RYLATT, D
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 1995, 6 (03) : 219 - 222
  • [9] BROWN B, 1984, HEMATOLOGY PRINCIPLE
  • [10] DETECTION OF YERSINIA-PESTIS FRACTION-1 ANTIGEN WITH A FIBER OPTIC BIOSENSOR
    CAO, LK
    ANDERSON, GP
    LIGLER, FS
    EZZELL, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (02) : 336 - 341