High resolution nuclear and X-ray microprobes and their applications in single cell analysis

被引:13
作者
Cholewa, M
Dillon, C
Lay, P
Phillips, D
Talarico, T
Lai, B
机构
[1] Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Univ Sydney, Sydney, NSW 2006, Australia
[3] La Trobe Univ, Bundoora, Vic 3083, Australia
[4] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
nuclear microprobe; X-ray microprobe; cell analysis;
D O I
10.1016/S0168-583X(01)00541-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Investigations of uptake of different chemical compounds by single cells have become a very popular topic and have been performed with different microanalytical techniques using electron, laser, ion and X-ray beams. With the advent of nuclear microprobes with submicron resolution it has been possible to investigate distribution of different elements inside individual cell with sensitivity of parts-per-million (ppm). Recently, with X-ray beams focused to 150 nm and high intensity obtained from third generation synchrotron facilities it became possible to perform analysis on a single cell with sensitivity of parts-per-billion (ppb). Synchrotron radiation offers also a unique possibility to investigate an oxidation state for different elements. In this paper, authors will present and discuss data from experiments on single cells performed with high resolution nuclear and X-ray microprobes. (C) 2001 Elsevier Science B.-V. All rights reserved.
引用
收藏
页码:715 / 722
页数:8
相关论文
共 23 条
[1]   Microscopic X-ray fluorescence analysis and related methods with laboratory and synchrotron radiation sources - Plenary lecture [J].
Adams, F ;
Janssens, K ;
Snigirev, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (05) :319-331
[2]   SYNCHROTRON X-RAY MICROPROBE DETERMINATION OF CHROMATE CONTENT USING X-RAY-ABSORPTION NEAR-EDGE STRUCTURE [J].
BAJT, S ;
CLARK, SB ;
SUTTON, SR ;
RIVERS, ML ;
SMITH, JV .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1800-1804
[3]   X-RAY OPTICS OF TAPERED CAPILLARIES [J].
BALAIC, DX ;
NUGENT, KA .
APPLIED OPTICS, 1995, 34 (31) :7263-7272
[4]  
BARA M, 1996, CELL MOL BIOL, V42
[5]   HIGH-RESOLUTION STIM [J].
BENCH, GS ;
LEGGE, GJF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 :655-658
[6]  
BIEDERMANN KA, 1990, CANCER RES, V50, P7835
[7]   MECHANISMS OF CHROMIUM CARCINOGENICITY AND TOXICITY [J].
COHEN, MD ;
KARGACIN, B ;
KLEIN, CB ;
COSTA, M .
CRITICAL REVIEWS IN TOXICOLOGY, 1993, 23 (03) :255-281
[8]   CHROMATE UPTAKE AND OXIDATION-STATE OF INTRACELLULAR CHROMIUM IN RAT THYMOCYTES [J].
DEBETTO, P ;
LAZZARINI, A ;
TOMASI, A ;
BELTRAME, M ;
ARSLAN, P .
CELL BIOLOGY INTERNATIONAL REPORTS, 1986, 10 (03) :214-214
[9]   Microprobe X-ray absorption spectroscopic determination of the oxidation state of intracellular chromium following exposure of V79 Chinese hamster lung cells to genotoxic chromium complexes [J].
Dillon, CT ;
Lay, PA ;
Cholewa, M ;
Legge, GJF ;
Bonin, AM ;
Collins, TJ ;
Kostka, KL ;
SheaMcCarthy, G .
CHEMICAL RESEARCH IN TOXICOLOGY, 1997, 10 (05) :533-535
[10]   Permeability, cytotoxicity, and genotoxicity of chromium(V) and chromium(VI) complexes in V79 Chinese hamster lung cells [J].
Dillon, CT ;
Lay, PA ;
Bonin, AM ;
Cholewa, M ;
Legge, GJF ;
Collins, TJ ;
Kostka, KL .
CHEMICAL RESEARCH IN TOXICOLOGY, 1998, 11 (02) :119-129