摘要
This paper describes an 8-probe system for scanning thermal microscopy. The design of the probe array, along with the choice of polyimide as the structural material provides very large compliance that virtually eliminates the need for z-axis mechanical feedback both at the chip and probe level in contact mode scans. The high compliance accommodates significant variations in the sample surface, and also prevents damage to soft samples. In addition, since integrated actuators and accompanying circuitry are no longer required, the prospect of scaling to large numbers of probes for high speed, high resolution thermal mapping of large areas with simple detection circuitry is enhanced. Based on single probes fabricated in the same process, the estimated spatial resolution, thermal conductance resolution, and temperature resolution are 50 nm, 11 pW/K, and 1.2 mK respectively. Scalability and performance of the 8-probe prototype are evaluated, addressing issues of speed vs. resolution, thermal and mechanical decoupling. Results demonstrate that contact mode scans can provide better than 2 mum spatial resolution at speeds greater than 200 mum/sec with each probe.
引用
收藏
页码:825 / 828
页数:4
相关论文
共 9 条
[1]   Integrated atomic force microscopy array probe with metal-oxide-semiconductor field effect transistor stress sensor, thermal bimorph actuator, and on-chip complementary metal-oxide-semiconductor electronics [J].
Akiyama, T ;
Staufer, U ;
de Rooij, NF ;
Lange, D ;
Hagleitner, C ;
Brand, O ;
Baltes, H ;
Tonin, A ;
Hidber, HR .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2000, 18 (06) :2669-2675
[2]   Parallel scanning AFM with on-chip circuitry in CMOS technology [J].
Lange, D ;
Akiyama, T ;
Hagleitner, C ;
Tonin, A ;
Hidber, HR ;
Niedermann, P ;
Staufer, U ;
de Rooij, NF ;
Brand, O ;
Baltes, H .
MEMS '99: TWELFTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 1999, :447-452
[3]   Microprobe array with electrical interconnection for thermal imaging and data storage [J].
Lee, DW ;
Ono, T ;
Abe, T ;
Esashi, M .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2002, 11 (03) :215-221
[4]   Applications of a low contact force polyimide shank bolometer probe for chemical and biological diagnostics [J].
Li, MH ;
Gianchandani, YB .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 104 (03) :236-245
[5]  
Miller SA, 1997, TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P455, DOI 10.1109/SENSOR.1997.613684
[6]   Automated parallel high-speed atomic force microscopy [J].
Minne, SC ;
Yaralioglu, G ;
Manalis, SR ;
Adams, JD ;
Zesch, J ;
Atalar, A ;
Quate, CF .
APPLIED PHYSICS LETTERS, 1998, 72 (18) :2340-2342
[7]   Micro-thermal analysis: techniques and applications [J].
Pollock, HM ;
Hammiche, A .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (09) :R23-R53
[8]   The "Millipede" -: More than one thousand tips for future AFM data storage [J].
Vettiger, P ;
Despont, M ;
Drechsler, U ;
Dürig, U ;
Häberle, W ;
Lutwyche, MI ;
Rothuizen, HE ;
Stutz, R ;
Widmer, R ;
Binnig, GK .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 2000, 44 (03) :323-340
[9]   SCANNING THERMAL PROFILER [J].
WILLIAMS, CC ;
WICKRAMASINGHE, HK .
APPLIED PHYSICS LETTERS, 1986, 49 (23) :1587-1589