Comparing laser ray tracing, the spatially resolved refractometer, and the Hartmann-Shack sensor to measure the ocular wave aberration

被引:96
作者
Moreno-Barriuso, E [1 ]
Marcos, S [1 ]
Navarro, R [1 ]
Burns, SA [1 ]
机构
[1] CSIC, Inst Opt Daza de Valdes, E-28006 Madrid, Spain
关键词
ocular aberrations; laser ray tracing; Hartmann-Shack; spatially resolved refractometer; aberrometer;
D O I
10.1097/00006324-200103000-00007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare quantitatively three techniques to measure the optical aberrations of the human eye: laser ray tracing (LRT), the Hartmann-Shack wavefront sensor (H-S), and the spatially resolved refractometer (SRR), LRT and H-S are objective imaging techniques, whereas SRR is psychophysical, Methods. Wave aberrations were measured in two normal subjects with all three techniques implemented in two different laboratories. Results. We compared the experimental variability of the results obtained with each technique with the overall Variability across the three methods. For the two subjects measured (RMS wavefront error 0.5 mum and 0.9 mum, respectively), we found a close agreement; the average standard deviation of the Zernike coefficients within a given method was 0.07 mum, whereas the average global standard deviation across techniques was 0.09 mum, which is only slightly higher, Conclusions. There is a close match between the Zernike coefficients obtained by LRT, H-S, and SRR. Thus, all three techniques provide similar information concerning wave aberration when applied to normal human eyes. However, the methods are operationally different, and each has advantages and disadvantages depending on the particular application.
引用
收藏
页码:152 / 156
页数:5
相关论文
共 26 条
[1]  
Born M., 1993, PRINCIPLES OPTICS EL
[2]  
Daniel M., 2006, Optical Shop Testing
[3]   Infrared imaging of sub-retinal structures in the human ocular fundus [J].
Elsner, AE ;
Burns, SA ;
Weiter, JJ ;
Delori, FC .
VISION RESEARCH, 1996, 36 (01) :191-205
[4]   Measurement of the wave-front aberration of the eye by a fast psychophysical procedure [J].
He, JC ;
Marcos, S ;
Webb, RH ;
Burns, SA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (09) :2449-2456
[5]  
Hofer H. J., 1998, IOVS, V39, pS203
[6]   Estimates of the ocular wave aberration from pairs of double-pass retinal images [J].
Iglesias, I ;
Berrio, E ;
Artal, P .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (09) :2466-2476
[7]   Supernormal vision and high-resolution retinal imaging through adaptive optics [J].
Liang, JZ ;
Williams, DR ;
Miller, DT .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) :2884-2892
[8]   OBJECTIVE MEASUREMENT OF WAVE ABERRATIONS OF THE HUMAN EYE WITH THE USE OF A HARTMANN-SHACK WAVE-FRONT SENSOR [J].
LIANG, JZ ;
GRIMM, B ;
GOELZ, S ;
BILLE, JF .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (07) :1949-1957
[9]   Aberrations and retinal image quality of the normal human eye [J].
Liang, JZ ;
Williams, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) :2873-2883
[10]  
Mierdel P, 1997, OPHTHALMOLOGE, V94, P441, DOI 10.1007/s003470050140