Amperometric H2O2 biosensor based on poly-thionine nanowire/HRP/nano-Au-modified glassy carbon electrode

被引:67
作者
Shi, Ai Wu [1 ]
Qu, Feng Li [1 ]
Yang, Ming Hui [1 ]
Shen, Guo Li [1 ]
Yu, Ru Qin [1 ]
机构
[1] Hunan Univ, Chem & Chem Engn Coll, State Key Lab Chemo Biosensing & Chemomet, Changsha 410082, Peoples R China
基金
中国国家自然科学基金;
关键词
alumina template membrane; thionine; electrodeposition; horseradish peroxidase; nano-Au; nanowires;
D O I
10.1016/j.snb.2007.09.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly-thionine nanowire/HRP/nano-Au composite nanomaterial was developed to fabricate the H2O2 biosensor. Poly-thionine nanowires (PTHNWs) have been synthesized by electrodeposition in porous anodic aluminum oxide (AAO) template. The morphological characterization of PTHNWs was examined by scanning electron microscopy (SEM) and transmission electron microscope (TEM). The nanowires prepared by this method can be used to encapsulate horseradish peroxidase (HRP) and nano-Au by in situ electrochemical copolymerization. The resulting PTHNWs-HRP-nano-Au material facilitates electron-transfer process in electrochemical sensor design. The PTHNWs-HRP-nano-Au film-modified electrode showed to be excellent amperometric sensors for H2O2. In pH 6.98 phosphate buffer, almost interference-free determination of H2O2 is realized at -0.1 V versus SCE with a linear range of 5 x 10(-7) to 1.3 x 10(-2) M, a correlation coefficient of 0.998 and response time <5 s. The sensitivity of the H2O2 biosensor is up to 168 mu A mM(-1) cm(-2) and the detection limit is 0.3 mu M. Furthermore, the biosensor exhibited long-term stability, and good reproducibility. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:779 / 783
页数:5
相关论文
共 35 条
[1]   Synthesis of CdS and ZnS nanowires using single-source molecular precursors [J].
Barrelet, CJ ;
Wu, Y ;
Bell, DC ;
Lieber, CM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (38) :11498-11499
[2]   Carbon nanotubule membranes for electrochemical energy storage and production [J].
Che, GL ;
Lakshmi, BB ;
Fisher, ER ;
Martin, CR .
NATURE, 1998, 393 (6683) :346-349
[3]   Electrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode [J].
Dai, Z ;
Chen, J ;
Yan, F ;
Ju, HX .
CANCER DETECTION AND PREVENTION, 2005, 29 (03) :233-240
[4]   COAGULATION OF COLLOIDAL GOLD [J].
ENUSTUN, BV ;
TURKEVICH, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1963, 85 (21) :3317-+
[5]   Amperometric hydrogen peroxide biosensor based on the immobilization of HRP on nano-Au/Thi/poly (p-aminobenzene sulfonic acid)-modified glassy carbon electrode [J].
Gao, Fengxian ;
Yuan, Ruo ;
Chai, Yaqin ;
Chen, Shihong ;
Cao, Shurui ;
Tang, Mingyu .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2007, 70 (03) :407-413
[6]   Preparation of poly(thionine) modified screen-printed carbon electrode and its application to determine NADH in flow injection analysis system [J].
Gao, Q ;
Cui, XQ ;
Yang, F ;
Ma, Y ;
Yang, XR .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) :277-282
[7]  
GARBAR C, 1995, ANAL CHEM, V67, P735
[8]   Silver nanoparticles doped silica nanocomposites coated on an optical fiber for ammonia sensing [J].
Guo, Haiquan ;
Tao, Shiquan .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) :578-582
[9]   HELICAL MICROTUBULES OF GRAPHITIC CARBON [J].
IIJIMA, S .
NATURE, 1991, 354 (6348) :56-58
[10]   Prussian Blue based nanoelectrode arrays for H2O2 detection [J].
Karyakin, AA ;
Puganova, EA ;
Budashov, IA ;
Kurochkin, IN ;
Karyakina, EE ;
Levchenko, VA ;
Matveyenko, VN ;
Varfolomeyev, SD .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :474-478