The effect of outdoor air and indoor human activity on mass concentrations of PM10, PM2.5, and PM1 in a classroom

被引:191
作者
Branis, M [1 ]
Rezácová, P [1 ]
Domasová, M [1 ]
机构
[1] Charles Univ, Inst Environm Studies, Fac Sci, Prague 12843 2, Czech Republic
关键词
indoor air pollution; particulate matter; coarse particle; PM10-2.5; schools;
D O I
10.1016/j.envres.2004.12.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The 12-h mass concentration of PM10, PM2.5, and PM1 was measured in a lecturing room by means of three co-located Harvard impactors. The filters were changed at 8 AM and at 8 PM to cover the periods of presence and absence of students. Concentrations were assessed by gravimetry. Ambient PM10 data were available for corresponding 12-h intervals from the nearest state air-quality-monitoring network station. The data were pooled into four periods according to the presence and absence of students-Monday-Thursday day (workday daytime), Monday-Thursday night (workday night), Friday-Sunday day (weekend daytime), and 3 Friday-Sunday night (weekend night). Average indoor workday daytime concentrations were 42.3, 21.9 and 13.7 mu g m(3), workday night were 20.9, 19.1 and 15.2 mu g m(-3), weekend daytime were 21.9, 18.1 and 11.4 mu g m(-3), and weekend night were 24.5, 21.3, and 15.6 mu g m-3 for PM10, PM2.5, and PM1, respectively. The highest 12-h mean, median, and maximum (42.3, 43.0, and 76.2 mu g m(-3), respectively) indoor concentrations were recorded on workdays during the daytime for PM10. The statistically significant (r = 0.68, P < 0.0009) correlation between the number Of Students per hour per day and the indoor coarse fraction calculated as PM10-2.5 during daytime on workdays indicates that the presence of people is an important source of coarse particles indoor. On workdays, the daytime PM10 indoor/outdoor ratio was positively associated (r = 0.93) with an increasing indoor coarse fraction (PM10-2.5), also indicating that an important portion of indoor PM10 had its source inside the classroom. With the exception of the calculated coarse fraction (PM10-2.5), all of the measured indoor particulate matter fractions were significantly highly correlated with outdoor PM10 and negatively correlated with wind velocity, showing that outdoor levels of particles influence their indoor concentrations. (c) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 45 条
[1]   Characterization of indoor particle sources: A study conducted in the metropolitan Boston area [J].
Abt, E ;
Suh, HH ;
Allen, G ;
Koutrakis, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (01) :35-44
[2]  
[Anonymous], 1995, AIR QUALITY MONOGRAP
[3]   Fine particles (PM1) in four different indoor environments [J].
Branis, M ;
Rezácová, P ;
Guignon, N .
INDOOR AND BUILT ENVIRONMENT, 2002, 11 (04) :184-190
[4]   Airborne coarse particles and mortality [J].
Castillejos, M ;
Borja-Aburto, VH ;
Dockery, DW ;
Gold, DR ;
Loomis, D .
INHALATION TOXICOLOGY, 2000, 12 :61-72
[5]   Influence of different indoor activities on the indoor particulate levels in residential buildings [J].
Chao, CYH ;
Tung, TCW ;
Burnett, J .
INDOOR AND BUILT ENVIRONMENT, 1998, 7 (02) :110-121
[6]   Effect of the fine fraction of particulate matter versus the coarse mass and other pollutants on daily mortality in Santiago, Chile [J].
Cifuentes, LA ;
Vega, J ;
Köpfer, K ;
Lava, LB .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (08) :1287-1298
[7]   Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information [J].
Daisey, JM ;
Angell, WJ ;
Apte, MG .
INDOOR AIR, 2003, 13 (01) :53-64
[8]   DUST FROM CARPETED AND SMOOTH FLOORS .6. ALLERGENS IN HOMES COMPARED WITH THOSE IN SCHOOLS IN NORWAY [J].
DYBENDAL, T ;
ELSAYED, S .
ALLERGY, 1994, 49 (04) :210-216
[9]   ALLERGENS IN SCHOOL DUST .2. MAJOR MITE (DER-P-I, DER-F-I) ALLERGENS IN DUST FROM SWEDISH SCHOOLS [J].
EINARSSON, R ;
MUNIR, AKM ;
DREBORG, SKG .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1995, 95 (05) :1049-1053
[10]   Time spent in the home by different family members [J].
Farrow, A ;
Taylor, H ;
Golding, J .
ENVIRONMENTAL TECHNOLOGY, 1997, 18 (06) :605-613