Cadmium detection via boron-doped diamond electrodes:: surfactant inhibited stripping voltarnmetry

被引:40
作者
Banks, CE [1 ]
Hyde, ME [1 ]
Tomcík, P [1 ]
Jacobs, R [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
基金
英国工程与自然科学研究理事会;
关键词
cadmium; sonoelectrochemistry; boron-doped diamond; ultrasound; atomic force microscopy;
D O I
10.1016/j.talanta.2003.07.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The deposition of cadmium on boron-doped diamond is investigated with square-wave anodic stripping voltammetry. The system was investigated in quiescent conditions, in the presence of an acoustic field and then in the presence of the neutral surfactant Triton(R) X-100. The effect of optimised insonation was to increase the sensitivity from 0.63 (under silent conditions) to 3.78 muA muM(-1) and to reduce the limit of detection by an order of magnitude from 10(-8) to 10(-9) M. Measurements with or without insonation were found to deteriorate in the presence of the surfactant. Studies using AFM and chronoamperometry showed that this was due to inhibition of the deposition of the metal. Comparative data obtained for analogous measurements for copper on glassy carbon in the presence of industrial effluent, which also leads to signal deterioration under silent but not insonated conditions, showed that for this case also it was the nucleation of copper rather than the metal dissolution which was adversely affected. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 46 条
  • [1] Anodic stripping voltammetry of copper at insonated glassy carbon-based electrodes:: application to the determination of copper in beer
    Agra-Gutiérrez, C
    Hardcastle, JL
    Ball, JC
    Compton, RG
    [J]. ANALYST, 1999, 124 (07) : 1053 - 1057
  • [2] Differential pulse anodic stripping voltammetric determination of copper(II) with N-phenylcinnamohydroxamic acid modified carbon paste electrodes
    Alemu, H
    Chandravanshi, BS
    [J]. ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) : 165 - 173
  • [3] AULIUKAITE R, 2002, ANAL BIOANAL CHEM, V374, P1155
  • [4] Banks CE, 2003, CHEM ANAL-WARSAW, V48, P159
  • [5] BANKS CE, 2003, CHEMPHYSCHEM, V4, P69
  • [6] BANKS CE, 2003, ELECTROANAL, V15, P10
  • [7] Stripping voltammetry in environmental and food analysis
    Brainina, KZ
    Malakhova, NA
    Stozhko, NY
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04): : 307 - 325
  • [8] Brett AMO, 1997, ULTRASON SONOCHEM, V4, P123
  • [9] Brett CMA, ELECTROCHEMISTRY PRI, V1st
  • [10] Square wave voltammetry on boron-doped diamond electrodes for analytical determinations
    Codognoto, L
    Machado, SAS
    Avaca, LA
    [J]. DIAMOND AND RELATED MATERIALS, 2002, 11 (09) : 1670 - 1675