Reliability and accuracy of different sensors of a flexible electrogoniometer

被引:37
作者
Shiratsu, A [1 ]
Coury, HJCG [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Phys Therapy, BR-13565905 Sao Carlos, SP, Brazil
关键词
electrogoniometer; reliability; accuracy;
D O I
10.1016/S0268-0033(03)00110-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To describe a gauging device for electrogoniometer sensors and to evaluate the reliability and accuracy of different sensors including two similar sensors. Design. Repeated measurement design for reliability. Background. Despite being considered reliable equipment, several aspects of electrogoniometer reliability and accuracy have not been reported so far. Method. Five repeated measurements of each electrogoniometer sensor were performed in 1degrees increments, during the whole uniplanar amplitudes of flexion, extension, lateral deviations and rotational movements, totaling 6380 measurements. Results. Values from the coefficient of variation and mean square error, respectively indicated that the reliability and accuracy of the sensors varied between sensors and movements, with goniometers being more reliable and accurate than torsiometers. A significant difference between identical sensors was identified. Conclusions. No similar pattern of variation was found between the sensors evaluated, indicating that every sensor should be tested for its reliability and accuracy when highly precise measurements are needed, and particularly when bilateral limbs are being compared.
引用
收藏
页码:682 / 684
页数:3
相关论文
共 7 条
[1]  
*BIOM LTD, 1997, GON TORS OP MAN GWEN
[2]   Effects of progressive levels of industrial automation on force and repetitive movements of the wrist [J].
Coury, HJCGC ;
Léo, JA ;
Kumar, S .
INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2000, 25 (06) :587-595
[3]   Goniometer measurement and computer analysis of wrist angles and movements applied to occupational repetitive work [J].
Hansson, GA ;
Balogh, I ;
Ohlsson, K ;
Rylander, L ;
Skerfving, S .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1996, 6 (01) :23-35
[4]   Comparison of measurement accuracy between two types of wrist goniometer systems [J].
Jonsson, P ;
Johnson, PW .
APPLIED ERGONOMICS, 2001, 32 (06) :599-607
[5]   Reliability of the American Medical Association Guides' model for measuring spinal range of motion - Its implication for whole-person impairment rating [J].
Nitschke, JE ;
Nattrass, CL ;
Disler, PB ;
Chou, MJ ;
Ooi, KT .
SPINE, 1999, 24 (03) :262-268
[6]   A new technique for the assessment of wrist movement using a biaxial flexible electrogoniometer [J].
Rawes, ML ;
Richardson, JB ;
Dias, JJ .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1996, 21B (05) :600-603
[7]  
Welsh AH, 1996, ASPECTS STAT INFEREN