Mass spectrometric analysis of DNA mixtures: Instrumental effects responsible for decreased sensitivity with increasing mass

被引:42
作者
Chen, XY [1 ]
Westphall, MS [1 ]
Smith, LM [1 ]
机构
[1] Univ Wisconsin, Dept Chem, Madison, WI 53706 USA
关键词
D O I
10.1021/ac030127h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Matrix-assisted laser absorption/ionization time-of-flight mass spectrometry has demonstrated great potential to replace gel electrophoresis for DNA sequence analysis. A current limitation in this method is, however, the decreased sensitivity with increasing mass of DNA molecules. In the present study, instrumental effects on the mass analysis of DNA molecules were investigated quantitatively using an equimolar DNA mixture. It is shown that detection efficiency, detector saturation, and ion beam divergence account for the entirety of the observed falloff in signal intensity with increasing mass. Although the present study focused upon the analysis of DNA mixtures, the instrumental effects observed apply equally to other macromolecular mixtures (e.g., proteins, polymers).
引用
收藏
页码:5944 / 5952
页数:9
相关论文
共 55 条
[11]   THE ANALYSIS OF MOCK DNA-SEQUENCING REACTIONS USING MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY [J].
FITZGERALD, MC ;
ZHU, L ;
SMITH, LM .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) :895-897
[12]   Molecular weight determination of megadalton DNA electrospray ions using charge detection time-of-flight mass spectrometry [J].
Fuerstenau, SD ;
Benner, WH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (15) :1528-1538
[13]   MATHEMATICAL-MODEL OF NON-CONTACT MEASUREMENTS OF CHARGES WHILE MOVING [J].
GAJEWSKI, JB .
JOURNAL OF ELECTROSTATICS, 1984, 15 (01) :81-92
[14]   SECONDARY-ELECTRON EMISSION INDUCED BY IMPACT OF LOW-VELOCITY MOLECULAR-IONS ON A MICROCHANNEL PLATE [J].
GENO, PW ;
MACFARLANE, RD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 92 :195-210
[15]  
Glückmann M, 1999, J MASS SPECTROM, V34, P467, DOI 10.1002/(SICI)1096-9888(199905)34:5<467::AID-JMS809>3.0.CO
[16]  
2-8
[17]   On the initial velocity of ions generated by matrix-assisted laser desorption ionization and its effect on the calibration of delayed extraction time-of-flight mass spectra [J].
Juhasz, P ;
Vestal, ML ;
Martin, SA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (03) :209-217
[18]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[19]  
Limbach PA, 1996, MASS SPECTROM REV, V15, P297, DOI 10.1002/(SICI)1098-2787(1996)15:5<297::AID-MAS2>3.0.CO
[20]  
2-D