Purpose. Inflammation and coagulation disturbances are common consequences of cardiopulmonary bypass (CPB). Recently, miniaturized closed CPB circuits without cardiotomy suction and venous reservoir have been proposed to reduce complication rates. We compared outcomes with conventional (CCPB) and miniaturized cardiopulmonary bypass (MCPB) after coronary artery bypass operations (CABG) with respect to inflammation and coagulation. Description. Thirty patients (23% female; aged 67.9 +/- 9.0 years) were prospectively randomly assigned to undergo isolated CABG with CCPB or MCPB. Conventional CPB had a pump prime of 1, 600 mL. Miniaturized CPB consisted of a centrifugal pump, arterial filter, heparinized tubing, and oxygenator with a priming volume of 800 mL. Shed blood was removed by a cell-saving device and reinfused. Measurements included interleukin (IL)-2 receptor, IL-6, IL-10, tumor necrosis factor receptor 55 and 75, C reactive protein, leukocyte differentiation, d-dimers, fibrinogen, and thrombocytes at six time points. Evaluation. In both groups no major complication occurred. However, two dangerous air leaks occurred in the closed MCPB circuit, demonstrating the narrow safety margins. Operative handling was also more difficult owing to limitations in venting and fluid management. International normalized ratio (p = 0.03) and antithrombin III (p = 0.04) levels were elevated during CPB in the CCPB group, most likely owing to differences of the intraoperative anticoagulation management. Repeated measures analysis revealed that not a single parameter of inflammation or clinical outcome showed significant differences among groups. Conclusions. Use of a MCPB affected inflammation and coagulation variables only marginally and did not lead to clinical relevant changes as assessed by blood loss, need for blood products, and intensive care unit and clinical stays. However, safety margins for volume loss, air emboli, and weaning from CPB decrease, because of the closed MCPB circuit.
引用
收藏
页码:2326 / 2332
页数:7
相关论文
共 18 条
[1]   Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits [J].
Aldea, GS ;
Soltow, LO ;
Chandler, WL ;
Triggs, CM ;
Vocelka, CR ;
Crockett, GI ;
Shin, YT ;
Curtis, WE ;
Verrier, ED .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (04) :742-755
[2]   Fat contamination of pericardial suction blood and its influence on in vitro capillary-pore flow properties in patients undergoing routine coronary artery bypass grafting [J].
Appelblad, M ;
Engström, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (02) :377-386
[3]   Systemic inflammation and cardiac surgery: an update [J].
Asimakopoulos, G .
PERFUSION-UK, 2001, 16 (05) :353-360
[4]   Intermittent antegrade hyperkalaemic warm blood cardioplegia supplemented with magnesium prevents myocardial substrate derangement in patients undergoing coronary artery bypass surgery [J].
Caputo, M ;
Bryan, AJ ;
Calafiore, AM ;
Suleiman, MS ;
Angelini, GD .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 14 (06) :596-601
[5]   Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation [J].
Fromes, Y ;
Gaillard, D ;
Ponzio, O ;
Chauffert, M ;
Gerhardt, MF ;
Deleuze, P ;
Bical, OM .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (04) :527-533
[6]   Requirement for renal replacement therapy in patients undergoing cardiac surgery [J].
Gummert, JF ;
Bucerius, J ;
Walther, T ;
Doll, N ;
Falk, V ;
Schmitt, DV ;
Mohr, FW .
THORACIC AND CARDIOVASCULAR SURGEON, 2004, 52 (02) :70-76
[7]   A prospective randomised comparison of cardiotomy suction and cell saver for recycling shed blood during cardiac surgery [J].
Jewell, AE ;
Akowuah, EF ;
Suvarna, SK ;
Braidley, P ;
Hopkinson, D ;
Cooper, G .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 23 (04) :633-636
[8]   A randomized comparison of off-pump and on-pump multivessel coronary-artery bypass surgery [J].
Khan, NE ;
De Souza, A ;
Mister, R ;
Flather, M ;
Clague, J ;
Davies, S ;
Collins, P ;
Wang, DL ;
Sigwart, U ;
Pepper, J .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (01) :21-28
[9]   Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility [J].
Moen, O ;
Fosse, E ;
Dregelid, E ;
Brockmeier, V ;
Andersson, C ;
Hogasen, K ;
Venge, P ;
Mollnes, TE ;
Kierulf, P .
ANNALS OF THORACIC SURGERY, 1996, 62 (04) :1134-1140
[10]   Miniaturized cardiopulmonary bypass in coronary artery bypass surgery: Marginal impact on inflammation and coagulation but loss of safety margins - Invited commentary [J].
Nollert, G ;
Schwabenland, I ;
Maktav, D ;
Kur, F ;
Christ, F ;
Fraunberger, P ;
Reichart, B ;
Vicol, C .
ANNALS OF THORACIC SURGERY, 2005, 80 (06) :2326-2332