Position-sensitive single-photon detection with a hybrid silicon pixel array tube

被引:8
作者
Gys, T
DAmbrosio, C
Heijne, E
Leutz, H
Piedigrossi, D
Puertolas, D
Rosso, E
机构
[1] CERN, Geneva
关键词
D O I
10.1016/S0168-9002(96)00975-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The hybrid Imaging Silicon Pixel Array (ISPA) tube combines the best aspects of image intensification with new possibilities offered by integrated electronics. The anode of the ISPA tube is a matrix of small silicon pixels directly detecting with a high spatial resolution electrons emitted by the photocathode. The pixels are individually bump-bonded to an integrated electronic read-out chip, allowing high gain, high speed and low noise. This paper presents a detailed study of the single-photon detection efficiency of the tube, and concludes with perspectives offered by the development of new electronics and tube designs.
引用
收藏
页码:131 / 133
页数:3
相关论文
共 7 条
[1]  
DAMBROSIO C, 1994, NUCL INSTRUM METH A, V338, P389, DOI 10.1016/0168-9002(94)91321-8
[2]   FIRST BEAM EXPOSURES OF A SCINTILLATING-FIBER TRACKER READ-OUT BY AN ISPA-TUBE [J].
DAMBROSIO, C ;
GYS, T ;
LEUTZ, H ;
PIEDIGROSSI, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (03) :618-621
[3]   A NEW POSITION-SENSITIVE PHOTON DETECTOR BASED ON AN IMAGING SILICON PIXEL ARRAY (ISPA-TUBE) [J].
GYS, T ;
DAMBROSIO, C ;
LEUTZ, H ;
PIEDIGROSSI, D ;
PUERTOLAS, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 355 (2-3) :386-389
[4]  
GYS T, UNPUB
[5]   LHC1: A semiconductor pixel detector readout chip with internal, tunable delay providing a binary pattern of selected events [J].
Heijne, EHM ;
Antinori, F ;
Barberis, D ;
Becks, KH ;
Beker, H ;
Beusch, W ;
Burger, P ;
Campbell, M ;
Cantatore, E ;
Catanesi, MG ;
Chesi, E ;
Darbo, G ;
DAuria, S ;
DaVia, C ;
DiBari, D ;
DiLiberto, S ;
Gys, T ;
Humpston, G ;
Jacholkowski, A ;
Jaeger, JJ ;
Jakubek, J ;
Jarron, P ;
Klempt, W ;
Krummenacher, F ;
Knudson, K ;
Kubasta, J ;
Lassalle, JC ;
Leitner, R ;
Lemeilleur, F ;
Lenti, V ;
Letheren, M ;
Lisowski, B ;
Lopez, L ;
Loukas, D ;
Luptak, M ;
Martinengo, P ;
Meddeler, G ;
Meddi, F ;
Middelkamp, P ;
Morando, M ;
Morettini, P ;
Munns, A ;
Musico, P ;
Pellegrini, F ;
Pengg, F ;
Pospisil, S ;
Quercigh, E ;
Ridky, J ;
Rossi, L ;
Safarik, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01) :55-63
[6]   INFLUENCE OF ELECTRON TRAPS ON CHARGE-COLLECTION EFFICIENCY IN GAAS RADIATION DETECTORS [J].
NAVA, F ;
CANALI, C ;
CASTALDINI, A ;
CAVALLINI, A ;
DAURIA, S ;
DELPAPA, C ;
FRIGERI, C ;
ZANOTTI, L ;
CETRONIO, A ;
LANZIERI, C ;
ZICHICHI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (01) :156-159
[7]   THE OPAL SILICON STRIP MICROVERTEX DETECTOR UPGRADE TO 2 COORDINATE READOUT [J].
HONMA, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3) :409-415