Toward reliable biomarker signatures in the age of liquid biopsies - how to standardize the small RNA-Seq workflow

被引:82
作者
Buschmann, Dominik [1 ,2 ]
Haberberger, Anna [1 ]
Kirchner, Benedikt [1 ]
Spornraft, Melanie [1 ]
Riedmaier, Irmgard [3 ,4 ]
Schelling, Gustav [5 ]
Pfaffl, Michael W. [1 ]
机构
[1] Tech Univ Munich, Dept Anim Physiol & Immunol, TUM Sch Life Sci Weihenstephan, Weihenstephaner Berg 3, D-85354 Freising Weihenstephan, Germany
[2] Univ Munich, Inst Human Genet, Univ Hosp, Goethestr 29, D-80336 Munich, Germany
[3] Tech Univ Munich, Dept Physiol, TUM Sch Life Sci Weihenstephan, Weihenstephaner Berg 3, D-85354 Freising Weihenstephan, Germany
[4] Eurofins Medigenomix Forensik GmbH, Anzinger Str 7a, D-85560 Ebersberg, Germany
[5] Univ Munich, Dept Anesthesiol, Univ Hosp, Marchioninistr 15, D-81377 Munich, Germany
关键词
GUIDELINES MINIMUM INFORMATION; PIWI-INTERACTING RNAS; GENE-EXPRESSION; DIFFERENTIAL EXPRESSION; MESSENGER-RNA; BIOCONDUCTOR PACKAGE; CLUSTERING METHODS; EXOSOME ISOLATION; QUALITY-CONTROL; FROZEN TISSUE;
D O I
10.1093/nar/gkw545
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Small RNA-Seq has emerged as a powerful tool in transcriptomics, gene expression profiling and biomarker discovery. Sequencing cell-free nucleic acids, particularly microRNA (miRNA), from liquid biopsies additionally provides exciting possibilities for molecular diagnostics, and might help establish disease-specific biomarker signatures. The complexity of the small RNA-Seq workflow, however, bears challenges and biases that researchers need to be aware of in order to generate high-quality data. Rigorous standardization and extensive validation are required to guarantee reliability, reproducibility and comparability of research findings. Hypotheses based on flawed experimental conditions can be inconsistent and even misleading. Comparable to the well-established MIQE guidelines for qPCR experiments, this work aims at establishing guidelines for experimental design and pre-analytical sample processing, standardization of library preparation and sequencing reactions, as well as facilitating data analysis. We highlight bottlenecks in small RNA-Seq experiments, point out the importance of stringent quality control and validation, and provide a primer for differential expression analysis and biomarker discovery. Following our recommendations will en-courage better sequencing practice, increase experimental transparency and lead to more reproducible small RNA-Seq results. This will ultimately enhance the validity of biomarker signatures, and allow reliable and robust clinical predictions.
引用
收藏
页码:5995 / 6018
页数:24
相关论文
共 247 条
[41]   Comparative analysis of clustering methods for gene expression time course data [J].
Costa, IG ;
de Carvalho, FDT ;
de Souto, MCP .
GENETICS AND MOLECULAR BIOLOGY, 2004, 27 (04) :623-631
[42]   SolexaQA: At-a-glance quality assessment of Illumina second-generation sequencing data [J].
Cox, Murray P. ;
Peterson, Daniel A. ;
Biggs, Patrick J. .
BMC BIOINFORMATICS, 2010, 11
[43]   Length and GC-biases during sequencing library amplification: A comparison of various polymerase-buffer systems with ancient and modern DNA sequencing libraries [J].
Dabney, Jesse ;
Meyer, Matthias .
BIOTECHNIQUES, 2012, 52 (02) :87-+
[44]   Preservation of RNA for functional analysis of separated alleles in yeast:: comparison of snap-frozen and RNALater® solid tissue storage methods [J].
Dekairelle, Anne-France ;
Van der Vorst, Sebastien ;
Tombal, Bertrand ;
Gala, Jean-Luc .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (10) :1283-1287
[45]   An Extensive Evaluation of Read Trimming Effects on Illumina NGS Data Analysis [J].
Del Fabbro, Cristian ;
Scalabrin, Simone ;
Morgante, Michele ;
Giorgi, Federico M. .
PLOS ONE, 2013, 8 (12)
[46]   The NBP Negative Binomial Model for Assessing Differential Gene Expression from RNA-Seq [J].
Di, Yanming ;
Schafer, Daniel W. ;
Cumbie, Jason S. ;
Chang, Jeff H. .
STATISTICAL APPLICATIONS IN GENETICS AND MOLECULAR BIOLOGY, 2011, 10 (01)
[47]   RNA quality assessment: a view from plant qPCR studies [J].
Die, Jose V. ;
Roman, Belen .
JOURNAL OF EXPERIMENTAL BOTANY, 2012, 63 (17) :6069-6077
[48]   Characterization of the 3′:5′ ratio for reliable determination of RNA quality [J].
Die, Jose V. ;
Obrero, Angeles ;
Gonzalez-Verdejo, Clara I. ;
Roman, Belen .
ANALYTICAL BIOCHEMISTRY, 2011, 419 (02) :336-338
[49]   A comprehensive evaluation of normalization methods for Illumina high-throughput RNA sequencing data analysis [J].
Dillies, Marie-Agnes ;
Rau, Andrea ;
Aubert, Julie ;
Hennequet-Antier, Christelle ;
Jeanmougin, Marine ;
Servant, Nicolas ;
Keime, Celine ;
Marot, Guillemette ;
Castel, David ;
Estelle, Jordi ;
Guernec, Gregory ;
Jagla, Bernd ;
Jouneau, Luc ;
Laloe, Denis ;
Le Gall, Caroline ;
Schaeffer, Brigitte ;
Le Crom, Stephane ;
Guedj, Mickael ;
Jaffrezic, Florence .
BRIEFINGS IN BIOINFORMATICS, 2013, 14 (06) :671-683
[50]   Substantial biases in ultra-short read data sets from high-throughput DNA sequencing [J].
Dohm, Juliane C. ;
Lottaz, Claudio ;
Borodina, Tatiana ;
Himmelbauer, Heinz .
NUCLEIC ACIDS RESEARCH, 2008, 36 (16)