The S-statistic as an early warning of entrainment in a fluidized bed dryer containing pharmaceutical granule

被引:24
作者
Chaplin, G
Pugsley, T [1 ]
Winters, C
机构
[1] Univ Saskatchewan, Dept Chem Engn, Saskatoon, SK S7N 5C5, Canada
[2] Merck Frosst Canada Inc, Kirkland, PQ H9H 3L1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
fluidization; drying; hydrodynamics; pharmaceuticals; S-statistic; conical fluidized bed; pressure fluctuations; entrainment; elutriation;
D O I
10.1016/j.powtec.2004.11.002
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The chaotic attractor comparison technique known as the S-statistic has been applied to pressure fluctuation data collected in a lab-scale fluidized bed dryer containing pharmaceutical granule. Along with pressure fluctuations, this unit has also been instrumented for measurements of bed temperature and fines entrainment. It has been determined that an increase in bed temperature, corresponding to the loss of granule surface moisture, occurs simultaneously with the onset of entrainment at a granule moisture content of approximately 11 wt.%. The S-statistic analysis is able to give an early warning of the undesirable hydrodynamic state where entrainment occurs provided an appropriate reference state is chosen. When a reference state of 10 wt.% moisture was chosen, a statistically similar hydrodynamic state was identified by the S-statistic occurring 8-9 min prior to the onset of entrainment, thus providing an early warning of this change. The monitoring of bed temperature alone provides no such early warning that entrainment is imminent. With further development, the S-statistic could become a valuable monitoring and control tool for the drying of granular material. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:148 / 156
页数:9
相关论文
共 14 条
  • [1] Chaotic behavior of fluidized beds based on pressure and voidage fluctuations
    Bai, D
    Bi, HT
    Grace, JR
    [J]. AICHE JOURNAL, 1997, 43 (05) : 1357 - 1361
  • [2] Application of chaos analysis to pressure fluctuation data from a fluidized bed dryer containing pharmaceutical granule
    Chaplin, G
    Pugsley, T
    Winters, C
    [J]. POWDER TECHNOLOGY, 2004, 142 (2-3) : 110 - 120
  • [3] CHAPLIN G, 2004, FLUIDIZATION, V11, P419
  • [4] Detecting differences between delay vector distributions
    Diks, C
    vanZwet, WR
    Takens, F
    DeGoede, J
    [J]. PHYSICAL REVIEW E, 1996, 53 (03): : 2169 - 2176
  • [5] CHARACTERIZATION OF STRANGE ATTRACTORS
    GRASSBERGER, P
    PROCACCIA, I
    [J]. PHYSICAL REVIEW LETTERS, 1983, 50 (05) : 346 - 349
  • [6] FREQUENCY-ANALYSIS OF PRESSURE FLUCTUATION IN FLUIDIZED-BED PLENUM
    KAGE, H
    IWASAKI, N
    YAMAGUCHI, H
    MATSUNO, Y
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1991, 24 (01) : 76 - 81
  • [7] Local differential pressure analysis in a slugging bed using deterministic chaos theory
    Karamavruc, AI
    Clark, NN
    [J]. CHEMICAL ENGINEERING SCIENCE, 1997, 52 (03) : 357 - 370
  • [8] Kunii D., 1991, FLUIDIZATION ENG
  • [9] MILLER RW, 1990, ASMEMFC3M1989
  • [10] DIAGNOSTIC PROCEDURES FOR ESTABLISHING THE QUALITY OF FLUIDIZATION OF GAS SOLID SYSTEMS
    SAXENA, SC
    RAO, NS
    TANJORE, VN
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1993, 6 (01) : 56 - 73