Real-Time IGBT Open-Circuit Fault Diagnosis in Three-Level Neutral-Point-Clamped Voltage-Source Rectifiers Based on Instant Voltage Error

被引:186
作者
Caseiro, Luis M. A. [1 ,2 ]
Mendes, Andre M. S. [1 ,2 ]
机构
[1] Univ Coimbra, Dept Elect & Comp Engn, P-3030290 Coimbra, Portugal
[2] Univ Coimbra, Inst Telecomunicacoes, P-3030290 Coimbra, Portugal
关键词
Fault detection; fault diagnosis; fault location; multilevel converters; neutral-point-clamped (NPC); rectifiers; reliability; semiconductor device breakdown; MOTOR-DRIVES; MULTILEVEL; CONVERTERS; TOLERANCE; TOPOLOGIES; ALGORITHM;
D O I
10.1109/TIE.2014.2341558
中图分类号
TP [自动化技术、计算机技术];
学科分类号
080201 [机械制造及其自动化];
摘要
This paper presents a real-time diagnostic algorithm for insulated-gate bipolar transistor open-circuit faults in three-level neutral-point-clamped rectifiers. This algorithm is based on the instant voltage error in the converter and requires only signals already available to the control system, avoiding the use of additional hardware. The algorithm is independent from the load and from the used control strategy and provides very fast detection and identification of the fault, with diagnostic times as low as two sample periods (in favorable conditions). Experimental results are presented for the operation of the rectifier with two distinct control and modulation strategies and in different conditions. Results show the algorithm's speed, effectiveness, and robustness.
引用
收藏
页码:1669 / 1678
页数:10
相关论文
共 42 条
[1]
Abadi MB, 2012, 2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), P1893, DOI 10.1109/ICElMach.2012.6350140
[2]
Switching Function Model-Based Fast-Diagnostic Method of Open-Switch Faults in Inverters Without Sensors [J].
An, Qun-Tao ;
Sun, Li-Zhi ;
Zhao, Ke ;
Sun, Li .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (01) :119-126
[3]
[Anonymous], 2011, 14 EUROPEAN C POWER
[4]
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System [J].
Antonio Rodriguez-Blanco, Marco ;
Claudio-Sanchez, Abraham ;
Theilliol, Didier ;
Gerardo Vela-Valdes, Luis ;
Sibaja-Teran, Pedro ;
Hernandez-Gonzalez, Leobardo ;
Aguayo-Alquicira, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1625-1633
[5]
Fault Diagnosis on a PWM Rectifier AC Drive System with Fault Tolerance Using the Average Current Park's Vector Approach [J].
Caseiro, J. A. A. ;
Mendes, A. M. S. ;
Marques Cardoso, A. J. .
2009 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE, VOLS 1-3, 2009, :695-701
[6]
Caseiro LMA, 2012, IEEE IND ELEC, P404, DOI 10.1109/IECON.2012.6388675
[7]
Fault-Tolerant Neutral-Point-Clamped Converter Solutions Based on Including a Fourth Resonant Leg [J].
Ceballos, Salvador ;
Pou, Josep ;
Zaragoza, Jordi ;
Robles, Eider ;
Luis Villate, Jose ;
Luis Martin, Jose .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (06) :2293-2303
[8]
Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System [J].
Choi, Ui-Min ;
Jeong, Hae-Gwang ;
Lee, Kyo-Beum ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (06) :2726-2739
[9]
da Silva E. R., 2006, PROC 37 IEEE PESC, P1
[10]
Fault detection and diagnosis in an induction machine drive: A pattern recognition approach based on concordia stator mean current vector [J].
Diallo, D ;
Benbouzid, MEH ;
Hamad, D ;
Pierre, X .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (03) :512-519