Triclinic oxy-hydroxyapatite

被引:34
作者
Alberius-Henning, P [1 ]
Adolfsson, E
Grins, J
Fitch, A
机构
[1] Stockholm Univ, Arrhenius Lab, SE-10691 Stockholm, Sweden
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
D O I
10.1023/A:1004876622105
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Partially dehydrated hydroxyapatite was characterised by X-ray powder diffraction (XRPD) using Guinier-Hagg films, diffractometer and high-resolution synchrotron data as a function of the degree of dehydration (DD). It is for the first time shown that the space group symmetry for partially dehydrated hydroxyapatite changes from hexagonal P6(3)/m to triclinic when more than ca. 35% of the structurally bound water is removed. With increasing DD the a- and b-axes decrease and the c-axis increases. At the highest DD value attained (78%) before the onset of a decomposition of the apatite, the cell parameters were determined to be a = 9.40023 (3), b = 9.39704 (3), c = 6.89967 (2) Angstrom, alpha = 90.0626 (2)degrees, beta = 89.7478 (1)degrees and gamma = 119.9971 (2)degrees. A structure refinement for this sample converged with R-F = 3.7% in space group P(1) over bar, using synchrotron data (lambda = 0.852790 Angstrom), 795 reflections in the 2 theta range 5-45 degrees and 62 positional parameters. The shifts of the atoms from their corresponding positions in hexagonal hydroxyapatite are small. A possible cause for the triclinic distortion is a tilting of the hydroxide ions in the apatite channels away from the channel axis. (C) 2001 Kluwer Academic Publishers.
引用
收藏
页码:663 / 668
页数:6
相关论文
共 25 条
[11]   AN AUTOMATIC MICRO-DENSITOMETER FOR X-RAY-POWDER DIFFRACTION PHOTOGRAPHS [J].
JOHANSSON, KE ;
PALM, T ;
WERNER, PE .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1980, 13 (12) :1289-1291
[12]   CRYSTAL STRUCTURE OF HYDROXYAPATITE [J].
KAY, MI ;
YOUNG, RA ;
POSNER, AS .
NATURE, 1964, 204 (496) :1050-&
[13]   PREPARATION AND THERMAL-PROPERTIES OF DENSE POLYCRYSTALLINE OXYHYDROXYAPATITE [J].
KIJIMA, T ;
TSUTSUMI, M .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1979, 62 (9-10) :455-460
[14]  
Larson A. C., 1987, LAUR86748 LOS AL NAT
[15]  
Levitt S R, 1969, J Biomed Mater Res, V3, P683, DOI 10.1002/jbm.820030413
[16]   THERMAL-BEHAVIOR OF HYDROXYAPATITE INTENDED FOR MEDICAL APPLICATIONS [J].
LOCARDI, B ;
PAZZAGLIA, UE ;
GABBI, C ;
PROFILO, B .
BIOMATERIALS, 1993, 14 (06) :437-441
[17]   OXYAPATITE (VOELCKERITE) PROBLEM [J].
MCCONNEL.D ;
HEY, MH .
MINERALOGICAL MAGAZINE, 1969, 37 (286) :301-&
[18]   PARAMAGNETIC HOLE-LIKE DEFECT IN IRRADIATED CALCIUM HYDROXYAPATITE SINGLE-CRYSTALS [J].
MENGEOT, M ;
BARTRAM, RH ;
GILLIAM, OR .
PHYSICAL REVIEW B, 1975, 11 (11) :4110-4124
[19]   NEW CALCIUM PHOSPHATE CERAMIC MATERIAL FOR BONE AND TOOTH IMPLANTS [J].
MONROE, EA ;
VOTAVA, W ;
BASS, DB ;
MCMULLEN, J .
JOURNAL OF DENTAL RESEARCH, 1971, 50 (04) :860-&
[20]   SINTERING EFFECTS ON THE STRENGTH OF HYDROXYAPATITE [J].
RUYS, AJ ;
WEI, M ;
SORRELL, CC ;
DICKSON, MR ;
BRANDWOOD, A ;
MILTHORPE, BK .
BIOMATERIALS, 1995, 16 (05) :409-415