A comparison of two time intervals for test-retest reliability of health status instruments

被引:540
作者
Marx, RG
Menezes, A
Horovitz, L
Jones, EC
Warren, RE
机构
[1] Hosp Special Surg, Sports Med & Shoulder Serv, New York, NY 10021 USA
[2] Hosp Special Surg, Ctr Clin Outcome Res, New York, NY 10021 USA
关键词
reliability; measurement; knee; retest; scale; instrument;
D O I
10.1016/S0895-4356(03)00084-2
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Studies of test-retest reliability for health-related quality of life instruments have used varying intervals between test administrations. There is no evidence available to aid in the selection of the time interval between questionnaire administrations for a study of test-retest reliability for health status instruments. We compared the test-retest reliability at 2 days and 2 weeks for four knee-rating scales and the eight domains of the SF-36. Seventy patients with disorders of the knee who were in a stable state were randomly allocated to repeat the questionnaires at either 2 days or 2 weeks. There were no statistically significant differences in the test-retest reliability (intraclass correlation coefficient and limits of agreement statistics) for the two time intervals. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:730 / 735
页数:6
相关论文
共 34 条
[1]
*AC ORTH SURG, 1998, SCOR ALG LOW LIMB OU
[2]
Allen M.J., 1979, Introduction to measurement theory
[3]
Anastasi A., 1988, Psychological testing
[4]
Anderson A.F., 1993, AM J KNEE SURG, V6, P67
[5]
Test-retest performance of a mailed version of the medical outcomes study 36-item short-form health survey among older adults [J].
Andresen, EM ;
Bowley, N ;
Rothenberg, BM ;
Panzer, R ;
Katz, P .
MEDICAL CARE, 1996, 34 (12) :1165-1170
[6]
[Anonymous], MED CARE
[7]
Validity and reproducibility of the Spanish version of the sickness impact profile [J].
Badia, X ;
Alonso, J .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1996, 49 (03) :359-365
[8]
Rigorous statistical reliability, validity, and responsiveness testing of the Cincinnati knee rating system in 350 subjects with uninjured, injured, or anterior cruciate ligament-reconstructed knees [J].
Barber-Westin, SD ;
Noyes, FR ;
McCloskey, JW .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (04) :402-416
[9]
COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[10]
A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) :337-340