Comparison of planar and SPECT scintimammography with 99mTc-sestamibi in the diagnosis of breast carcinoma

被引:15
作者
Danielsson, R [1 ]
Boné, B
Ågren, B
Svensson, L
Aspelin, P
机构
[1] Huddinge Univ Hosp, Dept Diagnost Radiol, Karolinska Inst, SE-14186 Huddinge, Sweden
[2] Huddinge Univ Hosp, Dept Hosp Phys, Karolinska Inst, SE-14186 Huddinge, Sweden
关键词
breast neoplasms; radionuclide studies;
D O I
10.3109/02841859909177734
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. To compare results of planar and SPECT breast imaging with Tc-99m-MIBI in detecting primary breast cancer. Material and Methods. Twenty-six consecutive patients with 34 suspected breast lesions underwent both planar and SPECT scintimammography. Ten minutes after injection of 700 MBq Tc-99m-MIBI, 2 prone lateral projections were obtained, followed by a supine anterior projection. Forty minutes after injection, a SPECT study was done. All lesions were operated upon and verified with histopathology. Results. A sensitivity of 85% and specificity of 88% of planar scintimammography in diagnosis of primary breast lesions were achieved. The corresponding values for SPECT were 61% and 64%. Conclusion: The diagnostic accuracy of planar scintimammography was not improved by using SPECT imaging.
引用
收藏
页码:176 / 180
页数:5
相关论文
共 12 条
[1]  
DIGGLES L, 1994, EUR J NUCL MED, V21, P28
[2]   Differentiation of benign and malignant breast lesions: MR imaging versus Tc-99m sestamibi scintimammography [J].
Helbich, TH ;
Becherer, A ;
Trattnig, S ;
Leitha, T ;
Kelkar, P ;
Seifert, M ;
Gnant, M ;
Staudenherz, A ;
Rudas, M ;
Wolf, G ;
Mostbeck, GH .
RADIOLOGY, 1997, 202 (02) :421-429
[3]  
KHALKHALI I, 1995, J NUCL MED, V36, P1784
[4]   REVIEW OF IMAGING TECHNIQUES FOR THE DIAGNOSIS OF BREAST-CANCER - A NEW ROLE OF PRONE SCINTIMAMMOGRAPHY USING TC-99M SESTAMIBI [J].
KHALKHALI, I ;
MENA, I ;
DIGGLES, L .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (04) :357-362
[5]  
LASTORIA S, 1994, J NUCL MED, V35
[6]   Scintigraphic imaging of breast tumors [J].
Maublant, J .
EUROPEAN JOURNAL OF RADIOLOGY, 1997, 24 (01) :2-10
[7]  
NAGARAJ N, 1994, J NUCL MED, V35, pN934
[8]   Scintimammography with technetium-99m methoxyisobutylisonitrile: results of a prospective European multicentre trial [J].
Palmedo, H ;
Biersack, HJ ;
Lastoria, S ;
Maublant, J ;
Prats, E ;
Stegner, HE ;
Bourgeois, P ;
Hustinx, R ;
Hilson, AJW ;
Bischof-Delaloye, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (04) :375-385
[9]  
Palmedo H, 1996, J NUCL MED, V37, P626
[10]  
TAILLEFER R, 1995, J NUCL MED, V36, P1758