Impact of coincidence on granulocyte-platelet complex determination by flow cytometry is evaluated by a novel computer simulation model of coincidence

被引:8
作者
Fent, Janos
Bihari, Peter [1 ]
Furesz, Jozsef
Hamar, Janos [1 ]
Lakatos, Susan
机构
[1] Natl Inst Traumatol, Budapest, Hungary
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 2008年 / 70卷 / 06期
基金
匈牙利科学研究基金会;
关键词
computer simulation; platelet-grarmlocyte complexes; coincidence; flow cytometry;
D O I
10.1016/j.jbbm.2007.07.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cell complexes composed of two different cells labeled with different fluorophores can be detected as double positive events in the flow cytometer. Double positivity can originate not only from real complexes but from non-interacting coinciding cells as well. Coincidence has a high impact on the determination of the amount of platelet-granulocyte complexes since platelet concentration is in the orders of magnitude higher than that of the granulocytes. A computer model has been developed to simulate coincidence in the flow cytometer to reveal the contribution of coincidence to the overestimation of the total amount of platelet-granulocyte complexes. Mixtures of non-interacting fluorescent beads as well as EDTA-anticoagulated blood samples were analyzed in the flow cytometer. An excellent fit was found between computer simulated and measured data pairs. Bead mixture in the flow cytometer and simulation of that resulted in 37.3 +/- 1.3 and 35.7 +/- 0.6% double positivity, respectively. 30.2 +/- 4.3% double positivity was measured for EDTA-anticoagulated blood samples while simulation of that resulted in 28.3 +/- 0.6%. Double positivity attributed to platelet-granulocyte complexes in slightly diluted blood samples might originate in coincidence and not from true complexes. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1086 / 1090
页数:5
相关论文
共 16 条
[1]   Increases in circulating levels of monocyte-platelet and neutrophil-platelet complexes following hip arthroplasty [J].
Bunescu, A ;
Widman, J ;
Lenkei, R ;
Menyes, P ;
Levin, K ;
Egberg, N .
CLINICAL SCIENCE, 2002, 102 (03) :279-286
[2]  
CHRISTOPHER S, 2004, CYTOMETRY, P63
[3]  
ERSLEV AJ, 1991, HEMATOLOGY, P423
[4]   Platelet function and platelet-leukocyte adhesion in symptomatic coronary heart disease. Effects of intravenous magnesium [J].
Gawaz, M ;
Reininger, A ;
Neumann, FJ .
THROMBOSIS RESEARCH, 1996, 83 (05) :341-349
[5]  
GAWAZ M, 1994, CLIN INVESTIGATOR, V72, P424
[6]  
Hagberg IA, 2000, PLATELETS, V11, P151
[7]  
HAMBURGER SA, 1990, BLOOD, V75, P550
[8]   Increased circulating platelet-leukocyte aggregates in myeloproliferative disorders is correlated to previous thrombosis, platelet activation and platelet count [J].
Jensen, MK ;
Brown, PD ;
Lund, BV ;
Nielsen, OJ ;
Hasselbalch, HC .
EUROPEAN JOURNAL OF HAEMATOLOGY, 2001, 66 (03) :143-151
[9]   COINCIDENCE IN HIGH-SPEED FLOW-CYTOMETRY - MODELS AND MEASUREMENTS [J].
KEIJ, JF ;
VANROTTERDAM, A ;
GROENEWEGEN, AC ;
STOKDIJK, W ;
VISSER, JWM .
CYTOMETRY, 1991, 12 (05) :398-404
[10]  
Li NL, 1999, CYTOMETRY, V35, P154, DOI 10.1002/(SICI)1097-0320(19990201)35:2<154::AID-CYTO7>3.0.CO