Ear oximetry:: A noninvasive method for detection of patent foramen ovale -: A study comparing dye dilution method and oximetry with contrast transesophageal echocardiography

被引:25
作者
Karttunen, V
Ventilä, M
Ikäheimo, M
Niemelä, M
Hillbom, M
机构
[1] Oulu Finland Univ Hosp, Dept Neurol, Oulu, Finland
[2] Oulu Finland Univ Hosp, Dept Cardiol, Oulu, Finland
[3] Univ Helsinki, Cent Hosp, Dept Cardiol, Helsinki, Finland
关键词
cerebrovascular disorders; echocardiography; transesophageal; foramen ovale; patent; oximetry;
D O I
10.1161/01.STR.32.2.448
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Patent foramen ovale (PFO) may play an important role as a risk factor for ischemic stroke and some other neurological conditions. There is a need for low-cost and noninvasive methods for the detection of PFO. This study evaluates the accuracy of two simple bedside tests, the dye dilution method and ear oximetry, in the detection of PFO, Methods-Dye dilution curves and ear oximetry recordings with a noninvasive ear densitometer were obtained from consecutive cryptogenic stroke patients referred fur contrast transcsophageal echocardiography (TEE), All test results were blindly assessed for the presence of PFO. Sensitivity and specificity were calculated with TEE used as a reference method. kappa statistics were used to measure interrater agreement. Results-Dye dilution curves were obtained from 67 patients. Dye dilution correctly diagnosed 35 of the 36 patients who had PFO in TEE and all the 21 patients without PFO. Thus, the sensitivity (95% CI) of the dye dilution method was 76% (61% to 87%) and its specificity 100% (84% to 100%). Ear oximetry was done on 83 patients. Oximetry correctly diagnosed 35 of the 53 patients who had PFO in TEE and an of the 30 patients without PFO, Thus, the sensitivity of ear oximetry was 85% (72% to 93%) and its: specificity 100% (88% to 100%), The interrater agreement was excellent (kappa value 0.94 for dye dilution and 0.90 fur oximetry). Conclusions-Dye dilution and oximetry are both sensitive and specific methods fur the detection of PFO, Oximetry has the following primary advantages over the currently available diagnostic methods: it is noninvasive, safe, and inexpensive and causes no discomfort for the patient. We suggest that oximetry could be used as a first-line screening method for PFO in patients with cryptogenic stroke. Ear oximetry also has potential use in epidemiological studies.
引用
收藏
页码:448 / 453
页数:6
相关论文
共 30 条
[1]   Potential source of cerebral embolism in migraine with aura - A transcranial Doppler study [J].
Anzola, GP ;
Magoni, M ;
Guindani, M ;
Rozzini, L ;
Dalla Volta, G .
NEUROLOGY, 1999, 52 (08) :1622-1625
[2]   SIMPLE TECHNIQUE FOR DETECTING SMALL DEFECTS OF ATRIAL SEPTUM [J].
BANAS, JS ;
MEISTER, SG ;
GAZZANIGA, AB ;
OCONNOR, NE ;
HAYNES, FW ;
DALEN, JE .
AMERICAN JOURNAL OF CARDIOLOGY, 1971, 28 (04) :467-+
[3]   COMPARISON OF TRANSESOPHAGEAL AND TRANSTHORACIC ECHOCARDIOGRAPHY WITH CONTRAST AND COLOR-FLOW DOPPLER IN THE DETECTION OF PATENT FORAMEN OVALE [J].
BELKIN, RN ;
POLLACK, BD ;
RUGGIERO, ML ;
ALAS, LL ;
TATINI, U .
AMERICAN HEART JOURNAL, 1994, 128 (03) :520-525
[4]   TRANSCARDIAC ECHOCARDIOGRAPHY DURING INVASIVE INTRAMEDULLARY PROCEDURES [J].
CHRISTIE, J ;
ROBINSON, CM ;
PELL, ACH ;
MCBIRNIE, J ;
BURNETT, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (03) :450-455
[5]   VENOARTERIAL SHUNTING IN OBSTRUCTIVE PULMONARY DISEASE [J].
DALY, JJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1968, 278 (17) :952-&
[6]   COMPARISON OF DIAGNOSTIC-TECHNIQUES FOR THE DETECTION OF A PATENT FORAMEN OVALE IN STROKE PATIENTS [J].
DITULLIO, M ;
SACCO, RL ;
VENKETASUBRAMANIAN, N ;
SHERMAN, D ;
MOHR, JP ;
HOMMA, S .
STROKE, 1993, 24 (07) :1020-1024
[7]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts - Comparison of different procedures and different contrast agents [J].
Droste, DW ;
Kriete, JU ;
Stypmann, J ;
Castrucci, M ;
Wichter, T ;
Tietje, R ;
Weltermann, B ;
Young, P ;
Ringelstein, EB .
STROKE, 1999, 30 (09) :1827-1832
[8]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Reproducibility, comparison of 2 agents, and distribution of microemboli [J].
Droste, DW ;
Reisener, M ;
Kemény, V ;
Dittrich, R ;
Schulte-Altedorneburg, G ;
Stypmann, J ;
Wichter, T ;
Ringelstein, EB .
STROKE, 1999, 30 (05) :1014-1018
[9]   Femoral injection of echo contrast medium may increase the sensitivity of testing for a patent foramen ovale [J].
Hamann, GF ;
Schätzer-Klotz, D ;
Fröhlig, G ;
Strittmatter, M ;
Jost, V ;
Berg, G ;
Stopp, M ;
Schimrigk, K ;
Schieffer, H .
NEUROLOGY, 1998, 50 (05) :1423-1428
[10]   Simultaneous bilateral contrast transcranial doppler monitoring in patients with intracardiac and intrapulmonary shunts [J].
Horner, S ;
Ni, XS ;
Weihs, W ;
Harb, S ;
Augustin, M ;
Duft, M ;
Niederkorn, K .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 1997, 150 (01) :49-57