Determination of ethanol in fuel ethanol and beverages by Fourier transform (FT)-near infrared and FT-Raman spectrometries

被引:131
作者
Mendes, LS [1 ]
Oliveira, FCC [1 ]
Suarez, PAZ [1 ]
Rubim, JC [1 ]
机构
[1] Univ Brasilia, Inst Quim, Lab Mat & Combust, BR-70919970 Brasilia, DF, Brazil
关键词
FT-NIR spectrometry; FT-Raman spectrometry; PLS; ethanol; alcoholic beverages;
D O I
10.1016/S0003-2670(03)00870-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fourier transform-near infrared (FT-NIR) and FT-Raman spectrometries have been used to design partial least squares (PLS) calibration models for the determination of the ethanol content of ethanol fuel and alcoholic beverages. In the FT-NIR measurements the spectra were obtained using air as reference, and the spectral region for PLS modeling were selected based on the spectral distribution of the relative standard deviation in concentration. In the FT-Raman measurements hexachloro-1,3-butadiene (HCBD) has been used as an external standard. In the PLS/FT-NIR modeling for ethanol fuel analysis 50 ethanol fuel standards (84.9-100% (w/w)) were used (25 in the calibration, 25 in the validation). In the PLS/FT-Raman modeling 25 standards were used (13 in the calibration, 12 in the validation). The PLS/FT-NIR and FT-Raman models for beverage analysis made use of 24 standards (0-100% (v/v)). Twelve of them contained sugars (1-5% (w/w)), one-half was used in the calibration and the other half in the validation. Different spectral pre-processing were used in the PLS modeling, depending on the type of sample investigated. In the ethanol fuel analysis the FT-NIR pre-processing was a 17 points smoothed first derivative and for beverages no spectral pre-processing was used. The FT-Raman spectra were pre-processed by vector normalization in the ethanol fuel analysis and by a second derivative (17 points smoothing) in the beverage analysis. The PLS models were used in the analysis of real ethanol fuel and beverage samples. A t-test has shown that the FT-NIR model has an accuracy equivalent to that of the reference method (ASTM D4052) in the analysis of ethanol fuel, while in the analysis of beverages, the FT-Raman model presents an accuracy equivalent to the reference method. The limits of detection for NIR and Raman calibration models were 0.05 and 0.2% (w/w), respectively. It has also been shown that both techniques, present better results than gas chromatography (GC) in evaluating the ethanol content of beverages. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:219 / 231
页数:13
相关论文
共 21 条
  • [1] Non-destructive and clean prediction of aviation fuel characteristics through Fourier transform-Raman spectroscopy and multivariate calibration
    Andrade, JM
    Garrigues, S
    de la Guardia, M
    Gómez-Carracedo, M
    Prada, D
    [J]. ANALYTICA CHIMICA ACTA, 2003, 482 (01) : 115 - 128
  • [2] *AOAC, 1998, OFF METH AN AOAC INT
  • [3] DIFFERENTIAL-PULSE POLAROGRAPHIC MICRODETERMINATION OF ETHANOL AND ITS APPLICATION TO BEER ANALYSIS
    CHAN, WH
    LEE, AWM
    CAI, PX
    [J]. ANALYST, 1992, 117 (09) : 1509 - 1512
  • [4] Infrared-induced isomerization of ethanol dimers trapped in argon and nitrogen matrices: Monochromatic irradiation experiments and DFT calculations
    Coussan, S
    Alikhani, ME
    Perchard, JP
    Zheng, WQ
    [J]. JOURNAL OF PHYSICAL CHEMISTRY A, 2000, 104 (23) : 5475 - 5483
  • [5] Dual-beam near-infrared Hadamard spectrophotometer
    da Silva, HEB
    Pasquini, C
    [J]. APPLIED SPECTROSCOPY, 2001, 55 (06) : 715 - 721
  • [6] dos Santos SRB, 2002, ANALYST, V127, P324
  • [7] STOPPED-FLOW NEAR-INFRARED SPECTROMETRIC DETERMINATION OF ETHANOL AND MALTOSE IN BEERS
    GALLIGNANI, M
    GARRIGUES, S
    DELAGUARDIA, M
    [J]. ANALYTICA CHIMICA ACTA, 1994, 296 (02) : 155 - 161
  • [8] DIRECT DETERMINATION OF ETHANOL IN ALL TYPES OF ALCOHOLIC BEVERAGES BY NEAR-INFRARED DERIVATIVE SPECTROMETRY
    GALLIGNANI, M
    GARRIGUES, S
    DELAGUARDIA, M
    [J]. ANALYST, 1993, 118 (09) : 1167 - 1173
  • [9] DERIVATIVE FOURIER-TRANSFORM INFRARED SPECTROMETRIC DETERMINATION OF ETHANOL IN ALCOHOLIC BEVERAGES
    GALLIGNANI, M
    GARRIGUES, S
    DELAGUARDIA, M
    [J]. ANALYTICA CHIMICA ACTA, 1994, 287 (03) : 275 - 283
  • [10] Evaluation of a dual-beam near-infrared spectrometer based on acousto-optic tunable filters
    Guchardi, R
    Pasquini, C
    [J]. APPLIED SPECTROSCOPY, 2001, 55 (04) : 454 - 457