Flow injection chemiluminescence determination of dobutamine hydrochloride injection using luminol-ferricyanide/ferrocyanide system

被引:32
作者
Liu, HY [1 ]
Zhang, L [1 ]
Zhou, JM [1 ]
Hao, YH [1 ]
He, PG [1 ]
Fang, YZ [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; flow injection; dobutamine hydrochloride;
D O I
10.1016/j.aca.2004.11.071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It was found that the weak chemiluminescence produced from the reaction of dobutamine hydrochloride with luminol in alkaline solution could be strongly enhanced by potassium ferricyanide and potassium ferrocyanide. Based on this found, a new flow injection chemiluminescence method is proposed for the determination of dobutamine hydrochloride. Under the optimum conditions, the proposed method has a linear range of 1.0 x 10(-10) to 1.0 X 10(-7) g ml(-1), with a detection limit of 2.6 x 10(-11) g ml(-1) for dobutamine hydrochloride (3 sigma). A complete analysis could be performed in 40 s including washing and sampling, giving a throughout of about 90 h(-1). The relative standard deviation (R.S.D.) for 11 parallel measurements of 1.0 x 10(-8) g ml(-1) dobutamine is 1.23%. The proposed method has been applied for the determination of dobutamine hydrochloride in its pharmaceutical formulations. The results obtained compared well with those by an official method. The possible mechanism of this chemiluminescence reaction was also proposed. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 18 条
[1]   CHEMILUMINESCENCE DETERMINATION OF IRON(II) AND TITANIUM(III) BY FLOW-INJECTION ANALYSIS BASED ON REACTIONS WITH AND WITHOUT LUMINOL [J].
ALWARTHAN, AA ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1987, 196 :135-140
[2]  
CHEN GN, 1998, CHEMILUMINESCENCE BI, P83
[3]  
*COMM CHIN PHARM, 1990, CHIN PHARM EX 2, P423
[4]  
*COMM CHIN PHARM, 1990, CHIN PHARM 2, P473
[5]   Flow injection chemiluminescence determination of epinephrine using epinephrine-imprinted polymer as recognition material [J].
Du, JX ;
Shen, LH ;
Lu, JR .
ANALYTICA CHIMICA ACTA, 2003, 489 (02) :183-189
[6]   Flow injection chemiluminescence determination of polyhydroxy phenols using luminol-ferricyanide/ferrocyanide system [J].
Du, JX ;
Li, YH ;
Lu, JR .
TALANTA, 2001, 55 (06) :1055-1058
[7]   Flow injection chemiluminescence determination of captopril based on its enhancing effect on the luminol-ferricyanide/ferrocyanide reaction [J].
Du, JX ;
Li, YH ;
Lu, JR .
LUMINESCENCE, 2002, 17 (03) :165-167
[8]  
FAN S, 2003, CHIN J INSTR ANAL, V22, P87
[9]   RAPID AND SENSITIVE ASSAY OF DOBUTAMINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL DETECTION [J].
HUSSEINI, H ;
MITROVIC, V ;
SCHLEPPER, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 620 (01) :164-168
[10]   Chemiluminescence flow injection analysis of reducing agents based on the luminol reaction [J].
Kubo, H ;
Toriba, A .
ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) :345-349