Contributions to reversed-phase column selectivity. I. Steric interaction

被引:48
作者
Carr, P. W. [2 ]
Dolan, J. W. [1 ]
Neue, U. D. [3 ]
Snyder, L. R. [1 ]
机构
[1] LC Resources Inc, Walnut Creek, CA USA
[2] Univ Minnesota, Minneapolis, MN USA
[3] Waters Corp, Milford, MA USA
关键词
Hydrophobic-subtraction; Steric interaction; Shape selectivity; Column selectivity; Retention mechanism; HPLC; PERFORMANCE LIQUID-CHROMATOGRAPHY; HYDROPHOBIC-SUBTRACTION MODEL; PRINCIPAL COMPONENT ANALYSIS; STATIONARY PHASES; SHAPE SELECTIVITY; SPECTROSCOPIC INVESTIGATIONS; RETENTION; CLASSIFICATION; SEPARATION; SOLUTES;
D O I
10.1016/j.chroma.2011.01.047
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In reversed-phase chromatography (RPC), the restricted retention of "bulky" solutes can occur in one of two ways, giving rise to either "shape selectivity" or "steric interaction." Starting with data for 150 solutes and 167 monomeric type-B alkylsilica columns, the present study examines the steric interaction process further and compares it with shape selectivity. The dependence of column hydrophobicity and steric interaction on column properties (ligand length and concentration, pore diameter, end-capping) was determined and compared. The role of the solute in steric interaction was found to be primarily a function of solute molecular length, with longer solutes giving increased steric interaction. We find that there are several distinct differences in the way shape selectivity and steric interaction are affected by separation conditions and the nature of the sample. Of particular interest, steric interaction exhibits a maximum effect for monomeric C-18 columns, and becomes less important for either a C-1 or C-30 column; shape selectivity appears unimportant for monomeric C-1-C-18 columns at ambient and higher temperatures, but becomes pronounced for C-30 as well as polymeric columns with ligands >= C-8. One hypothesis is that shape selectivity involves the presence or creation of cavities within the stationary phase that can accommodate a retained solute (a primarily enthalpic process), while steric interaction mainly makes greater use of spaces that pre-exist the retention of the solute (a primarily entropic process). The related dependence of hydrophobic interaction on column properties was also examined. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1724 / 1742
页数:19
相关论文
共 44 条
[1]  
AILAYA A, 1998, J CHROMATOGR A, V829, P1
[2]   New generation of chromatographic packings and columns for determination of biologically active compounds [J].
Buszewski, B ;
Kowalska, S ;
Krupczynska, K .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2005, 35 (02) :89-116
[3]  
CARR PW, 1993, J CHROMATOGR A, V656, P381
[4]   Relevance of π-π and dipole-dipole interactions for retention on cyano and phenyl columns in reversed-phase liquid chromatography [J].
Croes, K ;
Steffens, A ;
Marchand, DH ;
Snyder, LR .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1098 (1-2) :123-130
[5]   Selecting an "orthogonal" column during high-performance liquid chromatographic method development for samples that may contain non-ionized solutes [J].
Dolan, J. W. ;
Snyder, L. R. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (16) :3467-3472
[6]   Choosing an equivalent replacement column for a reversed-phase liquid chromatographic assay procedure [J].
Dolan, JW ;
Maule, A ;
Bingley, D ;
Wrisley, L ;
Chan, CC ;
Angod, M ;
Lunte, C ;
Krisko, R ;
Winston, JM ;
Homeier, BA ;
McCalley, DV ;
Snyder, LR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1057 (1-2) :59-74
[7]   HYDROPHOBICITY ESTIMATIONS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY - IMPLICATIONS FOR BIOLOGICAL PARTITIONING PROCESSES [J].
DORSEY, JG ;
KHALEDI, MG .
JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) :485-499
[8]  
EGELHAAF HJ, 1997, J FLUORESC, V7, P311
[9]   Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns using principal component analysis [J].
Euerby, M ;
Petersson, P .
JOURNAL OF CHROMATOGRAPHY A, 2003, 994 (1-2) :13-36
[10]   Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns containing phenyl moieties using principal component analysis [J].
Euerby, Melvin R. ;
Petersson, Patrik ;
Campbell, William ;
Roe, Wendy .