Biomechanics of transfixation in pedicle screw instrumentation

被引:65
作者
Lim, TH
Eck, JC
An, HS
Hong, JH
Ahn, JY
You, JW
机构
[1] MARQUETTE UNIV,DEPT BIOMED ENGN,MILWAUKEE,WI 53233
[2] CHEIL GEN HOSP,DEPT ORTHOPAED SURG,SEOUL,SOUTH KOREA
[3] CHOSUN UNIV,DEPT ORTHOPAED SURG,KWANGJU 501759,SOUTH KOREA
关键词
biomechanics; finite element analysis; pedicle screw instrumentation; spinal stability; transfixation;
D O I
10.1097/00007632-199610010-00009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. The biomechanical role of transfixation in pedicle screw instrumentation was investigated using flexibility tests and finite element analyses. Objective. To assess the stabilizing effect of use and position of transfixators. Summary of Background Data. Transfixation is common in pedicle screw instrumentation, however, its biomechanical role and optimal position are not completely understood. Methods. Specimens underwent nondestructive flexibility tests using a three-dimensional motion analysis system. Tests compared the intact spine with instrumentation with and without transfixators. Rotational angles of the superior vertebra, resulting from the maximum moment of 6.4 Nm, were compared. Three-dimensional finite element models investigated transfixator position. Rotations of the superior vertebra were compared for cases with and without transfixators to determine the position providing the greatest stability. Results. Biomechanical test showed that only axial rotational stability significantly improved with transfixators compared with instrumentation alone. Finite element models predicted improvement in lateral bending and axial rotation with transfixators compared with the case with no transfixator. With one transfixator, the greatest improvement in axial rotation stability occurred with the transfixator at the proximal 1/4 position of the rods, When two transfixators were used, the optimal locations were with one transfixator in the middle and the second at the proximal 1/8 position. Conclusions. Transfixators improved the stabilizing effects of pedicle screw instrumentation. The greatest axial rotation stability was obtained with two transfixators: one in the middle and the other at the proximal iis position of the longitudinal rods.
引用
收藏
页码:2224 / 2229
页数:6
相关论文
共 30 条
[1]  
ABUMI K, 1989, SPINE, V14, P1239
[2]   BIOMECHANICAL ANALYSIS OF PEDICLE SCREW INSTRUMENTATION SYSTEMS IN A CORPECTOMY MODEL [J].
ASHMAN, RB ;
GALPIN, RD ;
CORIN, JD ;
JOHNSTON, CE .
SPINE, 1989, 14 (12) :1398-1405
[3]   INTERNAL FORCES AND MOMENTS IN TRANSPEDICULAR SPINE INSTRUMENTATION - THE EFFECT OF PEDICLE SCREW ANGLE AND TRANSFIXATION - THE 4R-4BAR LINKAGE CONCEPT [J].
CARSON, WL ;
DUFFIELD, RC ;
ARENDT, M ;
RIDGELY, BJ ;
GAINES, RW .
SPINE, 1990, 15 (09) :893-901
[4]   INFLUENCE OF BONE-MINERAL DENSITY ON THE FIXATION OF THORACOLUMBAR IMPLANTS - A COMPARATIVE-STUDY OF TRANSPEDICULAR SCREWS, LAMINAR HOOKS, AND SPINOUS PROCESS WIRES [J].
COE, JD ;
WARDEN, KE ;
HERZIG, MA ;
MCAFEE, PC .
SPINE, 1990, 15 (09) :902-907
[5]   COMPARISON OF IN-VIVO AND IN-VITRO ADJACENT SEGMENT MOTION AFTER LUMBAR FUSION [J].
DEKUTOSKI, MB ;
SCHENDEL, MJ ;
OGILVIE, JW ;
OLSEWSKI, JM ;
WALLACE, LJ ;
LEWIS, JL .
SPINE, 1994, 19 (15) :1745-1751
[6]  
DICK JC, 1993, P NASS
[7]   LONGITUDINAL ELEMENT SIZE EFFECT ON LOAD SHARING, INTERNAL LOADS, AND FATIGUE LIFE OF TRI-LEVEL SPINAL IMPLANT CONSTRUCTS [J].
DUFFIELD, RC ;
CARSON, WL ;
CHEN, LY ;
VOTH, B .
SPINE, 1993, 18 (12) :1695-1703
[8]   EXPERIMENTAL EVALUATION OF 7 DIFFERENT SPINAL FRACTURE INTERNAL-FIXATION DEVICES USING NONFAILURE STABILITY TESTING - THE LOAD-SHARING AND UNSTABLE-MECHANISM CONCEPTS [J].
GAINES, RW ;
CARSON, WL ;
SATTERLEE, CC ;
GROH, GI .
SPINE, 1991, 16 (08) :902-909
[9]   AN ANALYTICAL INVESTIGATION OF THE MECHANICS OF SPINAL INSTRUMENTATION [J].
GOEL, VK ;
KIM, YE ;
LIM, TH ;
WEINSTEIN, JN .
SPINE, 1988, 13 (09) :1003-1011
[10]   MECHANICAL-PROPERTIES OF LUMBAR SPINAL MOTION SEGMENTS AS AFFECTED BY PARTIAL DISK REMOVAL [J].
GOEL, VK ;
NISHIYAMA, K ;
WEINSTEIN, JN ;
LIU, YK .
SPINE, 1986, 11 (10) :1008-1012