Direct oxidation of ascorbic acid at an edge plane pyrolytic graphite electrode: A comparison of the electroanalytical response with other carbon electrodes

被引:102
作者
Wantz, F [1 ]
Banks, CE [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
ascorbic acid; direct oxidation; edge plane pyrolytic graphite electrode; basal plane pyrolytic graphite electrode; glassy carbon electrode; boron doped diamond electrode;
D O I
10.1002/elan.200503259
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The direct electrochemical oxidation of ascorbic acid at an edge plane pyrolytic graphite electrode (EPPG) is investigated and compared with other common carbon-based electrodes, specifically glassy carbon, boron doped diamond and basal plane pyrolytic graphite. It is found that the EPPG electrode shows a significantly higher degree of electrochemical reversibility than the other electrode substrates giving rise to an analytically optimized limit of detection and sensitivity of 7.1 x 10(-5) M and 0.065 A M-1 respectively.
引用
收藏
页码:1529 / 1533
页数:5
相关论文
共 35 条
[1]  
ALBRECHT JA, 1990, J LIQ CHROMATOGR, V13, P2633, DOI 10.1080/01483919008049059
[2]   Exploration of gas sensing possibilities with edge plane pyrolytic graphite electrodes: nitrogen dioxide detection [J].
Banks, CE ;
Goodwin, A ;
Heald, CGR ;
Compton, RG .
ANALYST, 2005, 130 (03) :280-282
[3]   Investigation of modified basal plane pyrolytic graphite electrodes: definitive evidence for the electrocatalytic properties of the ends of carbon nanotubes [J].
Banks, CE ;
Moore, RR ;
Davies, TJ ;
Compton, RG .
CHEMICAL COMMUNICATIONS, 2004, (16) :1804-1805
[4]   An assay for ascorbic acid based on polyaniline-coated microplates [J].
Bossi, A ;
Piletsky, SA ;
Piletska, EV ;
Righetti, PG ;
Turner, APF .
ANALYTICAL CHEMISTRY, 2000, 72 (18) :4296-4300
[5]   FLOW-INJECTION ANALYSIS WITH AN ENZYME REACTOR BED FOR DETERMINATION OF ASCORBIC-ACID IN BRAIN-TISSUE [J].
BRADBERRY, CW ;
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2439-2440
[6]   DETERMINATION OF TOTAL VITAMIN-C IN FRUITS BY CAPILLARY ZONE ELECTROPHORESIS [J].
CHIARI, M ;
NESI, M ;
CARREA, G ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (01) :197-200
[7]   Sonovoltammetric behavior of ascorbic acid and dehydroascorbic acid at glassy carbon electrodes: Analysis using pulsed sonovoltammetry [J].
Compton, RG ;
Matysik, FM .
ELECTROANALYSIS, 1996, 8 (03) :218-222
[8]   DIFFUSION-PROCESSES MEASURED AT MICROVOLTAMMETRIC ELECTRODES IN BRAIN-TISSUE [J].
DAYTON, MA ;
EWING, AG ;
WIGHTMAN, RM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 146 (01) :189-200
[9]   COMPARISON OF VOLTAMMETRIC AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR ASCORBIC-ACID DETERMINATION IN INFANT FORMULAS [J].
ESTEVE, MJ ;
FARRE, R ;
FRIGOLA, A ;
LOPEZ, JC ;
ROMERA, JM ;
RAMIREZ, M ;
GIL, A .
FOOD CHEMISTRY, 1995, 52 (01) :99-102
[10]   Sensitive spectrophotometric determination of ascorbic acid in fruit juices and pharmaceutical formulations using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Br-PADAP) [J].
Ferreira, SLC ;
Bandeira, MLSF ;
Lemos, VA ;
dosSantos, HC ;
Costa, ACS ;
deJesus, DS .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (08) :1174-1178