Potential role of intensity modulated proton beams in prostate cancer radiotherapy

被引:48
作者
Cella, L
Lomax, A
Miralbell, R
机构
[1] Univ Hosp Geneva, Dept Radiat Oncol, Geneva, Switzerland
[2] Paul Scherrer Inst, Div Radiat Med, Villigen, Switzerland
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 49卷 / 01期
关键词
prostate cancer; dose escalation; intensity modulated radiotherapy; proton therapy; conformal radiotherapy;
D O I
10.1016/S0360-3016(00)01368-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The present study was undertaken to assess the potential benefit of intensity modulated (IM) proton beams in optimizing the dose distribution to safely escalate the tumor dose in prostate cancer radiotherapy. Methods and Materials: Four treatment plans were compared in a prostate cancer patient aiming to deliver 81 Gy to the target: 1) conformal 18 MV X-rays, 6-fields; 2) 214 MeV protons, 2-fields; 3) IM 15 MV X-rays, 5-fields; and 4) 177-200 Mev IM protons, 5-fields as in Plan 3. In addition, IM methods were used to further escalate the tumor dose to 99 Gy, Dose-volume histograms (DVH) were used to physically compare the treatment plans. DVH data were also used to obtain normal tissue complication probabilities (NTCP) for the rectum, bladder, femoral heads, and tumor control probabilities. Results: Although the planning target volume dose distribution was satisfactory with the four treatment plans, the homogeneity was slightly reduced in both X-ray plans (IM and standard) and the low-to-medium doses delivered to all organs at risk, and other normal tissues were significantly reduced by both proton plans. For a prescribed dose of 81 Gy, only the IM X-ray and IM proton plans both succeeded in predicting an acceptably low NTCP for the rectum (< 5 %, Grade 3). The integral nontarget dose was significantly reduced with IM proton beams (i.e., 3.1, 1.3, and 1.7 times less than Plans 1, 2, and 3,respectively). When escalating the dose to 99 Gy, no additional improvement between IM protons and LM X-ray beams was observed. Conclusions: Both WI X-ray and proton beams were able to optimize the dose distribution and comply with the goal of delivering the highest dose to the target while reducing the risk of severe morbidity to acceptable levels. The main advantage compared to IM X-rays was that WI protons succeeded in significantly reducing the low-to-medium dose to the nontarget tissues and achieved a small improvement in planning target volume (PTV) dose heterogeneity. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 32 条
[1]   Perineural invasion and Gleason 7-10 tumors predict increased failure in prostate cancer patients with pretreatment PSA&lt;10 ng/ml treated with conformal external beam radiation therapy [J].
Anderson, PR ;
Hanlon, AL ;
Patchefsky, A ;
Al-Saleem, T ;
Hanks, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (05) :1087-1092
[2]   LATE RECTAL BLEEDING FOLLOWING COMBINED X-RAY AND PROTON HIGH-DOSE IRRADIATION FOR PATIENTS WITH STAGES T3-T4 PROSTATE CARCINOMA [J].
BENK, VA ;
ADAMS, JA ;
SHIPLEY, WU ;
URIE, MM ;
MCMANUS, PL ;
EFIRD, JT ;
WILLETT, CG ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (03) :551-557
[3]   Reproducibility of conformal radiation therapy in localized carcinoma of the prostate without rigid immobilization [J].
Bieri, S ;
Miralbell, R ;
Nouet, P ;
Delorme, H ;
Rouzaud, M .
RADIOTHERAPY AND ONCOLOGY, 1996, 38 (03) :223-230
[4]  
BORTFELD T, 1992, ADV RAD THERAPY TUMO, P503
[5]   OPTIMIZATION OF RADIATION-THERAPY [J].
BRAHME, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :785-787
[6]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[7]   Comparison of radiation side-effects of conformal and conventional radiotherapy in prostate cancer: a randomised trial [J].
Dearnaley, DP ;
Khoo, VS ;
Norman, AR ;
Meyer, L ;
Nahum, A ;
Tait, D ;
Yarnold, J ;
Horwich, A .
LANCET, 1999, 353 (9149) :267-272
[8]  
GOITEIN M, 1987, REPORT WORKING GROUP
[9]   THE EFFECT OF DOSE ON LOCAL-CONTROL OF PROSTATE-CANCER [J].
HANKS, GE ;
MARTZ, KL ;
DIAMOND, JJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (06) :1299-1305
[10]  
JACKSON A, 2000, INT J RADIAT ONCOL, V46, P702