Electrophoretic separations on chips with hydrodynamically closed separation systems

被引:65
作者
Kaniansky, D
Masár, M
Bodor, R
Zúborová, M
Ölveckä, E
Jöhnck, M
Stanislawski, B
机构
[1] Comenius Univ, Fac Sci, Dept Analyt Chem, Bratislava 84215, Slovakia
[2] Merck KGaA, Darmstadt, Germany
关键词
column-coupling chips; detection on chips; electrophoresis on chips; miniaturization review; sample pretreatment on chips;
D O I
10.1002/elps.200305474
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This review focuses on capillary electrophoretic separations performed on capillary electrophoresis chips (CE chips) with hydrodynamically closed separation systems in a context with transport processes (electroosmotic flow (EOF)) and hydrodynamic flow (HDF)) that may accompany the separations in these devices. It also reflects some relevant works dealing with conventional CE operating under such hydrodynamic conditions. The use of zone electrophoresis (ZE), isotachophoresis (ITP) and their on-line combination (ITP-ZE) on the single-column and column-coupling CE chips with the closed separation systems and related problems are key topics of the review. Some attention is paid to sample pretreatment in the separations performed on the CE chips. Here, mainly potentialities of the ITP-ZE combination in trace analysis applications of the miniaturized systems are discussed in a broader extent. Links between the ZE separation and detection provide a frame for the discussion of current status of the detection on the CE chips. Analytical applications illustrate potentialities of the CE chips operating with the closed separation systems (suppressed HDF and EOF) to the determination of small ions present in various matrices by ZE, ITP and ITP-ZE.
引用
收藏
页码:2208 / 2227
页数:20
相关论文
共 158 条
[1]   ISOTACHOPHORESIS IN OPEN SYSTEMS - PROBLEMS IN QUANTITATIVE-ANALYSIS [J].
ACKERMANS, MT ;
EVERAERTS, FM ;
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY, 1991, 545 (02) :283-297
[2]   Molecular fluorescence, phosphorescence, and chemiluminescence spectrometry [J].
Agbaria, RA ;
Oldham, PB ;
McCarroll, M ;
McGown, LB ;
Warner, IM .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :3952-3962
[3]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[4]  
BABA Y, 2002, MICROTOTAL ANAL SYST
[5]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[6]   ISOTACHOPHORESIS WITH 2 LEADING IONS AND MIGRATION BEHAVIOR IN CAPILLARY ZONE ELECTROPHORESIS .2. MIGRATION BEHAVIOR IN CAPILLARY ZONE ELECTROPHORESIS [J].
BECKERS, JL ;
EVERAERTS, FM .
JOURNAL OF CHROMATOGRAPHY, 1990, 508 (01) :19-26
[7]   ISOTACHOPHORESIS WITH 2 LEADING IONS AND MIGRATION BEHAVIOR IN CAPILLARY ZONE ELECTROPHORESIS .1. ISOTACHOPHORESIS WITH 2 LEADING IONS [J].
BECKERS, JL ;
EVERAERTS, FM .
JOURNAL OF CHROMATOGRAPHY, 1990, 508 (01) :3-17
[8]   ISOTACHOPHORESIS WITH ELECTROOSMOTIC FLOW - OPEN VERSUS CLOSED SYSTEMS [J].
BECKERS, JL ;
EVERAERTS, FM ;
ACKERMANS, MT .
JOURNAL OF CHROMATOGRAPHY, 1991, 537 (1-2) :429-442
[9]  
Beckers JL, 2000, ELECTROPHORESIS, V21, P2747, DOI 10.1002/1522-2683(20000801)21:14<2747::AID-ELPS2747>3.0.CO
[10]  
2-Z