Electrophoretic separations on chips with hydrodynamically closed separation systems

被引:65
作者
Kaniansky, D
Masár, M
Bodor, R
Zúborová, M
Ölveckä, E
Jöhnck, M
Stanislawski, B
机构
[1] Comenius Univ, Fac Sci, Dept Analyt Chem, Bratislava 84215, Slovakia
[2] Merck KGaA, Darmstadt, Germany
关键词
column-coupling chips; detection on chips; electrophoresis on chips; miniaturization review; sample pretreatment on chips;
D O I
10.1002/elps.200305474
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This review focuses on capillary electrophoretic separations performed on capillary electrophoresis chips (CE chips) with hydrodynamically closed separation systems in a context with transport processes (electroosmotic flow (EOF)) and hydrodynamic flow (HDF)) that may accompany the separations in these devices. It also reflects some relevant works dealing with conventional CE operating under such hydrodynamic conditions. The use of zone electrophoresis (ZE), isotachophoresis (ITP) and their on-line combination (ITP-ZE) on the single-column and column-coupling CE chips with the closed separation systems and related problems are key topics of the review. Some attention is paid to sample pretreatment in the separations performed on the CE chips. Here, mainly potentialities of the ITP-ZE combination in trace analysis applications of the miniaturized systems are discussed in a broader extent. Links between the ZE separation and detection provide a frame for the discussion of current status of the detection on the CE chips. Analytical applications illustrate potentialities of the CE chips operating with the closed separation systems (suppressed HDF and EOF) to the determination of small ions present in various matrices by ZE, ITP and ITP-ZE.
引用
收藏
页码:2208 / 2227
页数:20
相关论文
共 158 条
[51]   TRANSPORT, SPACE, ENTROPY, DIFFUSION AND FLOW - ELEMENTS UNDERLYING SEPARATION BY ELECTROPHORESIS, CHROMATOGRAPHY, FIELD-FLOW FRACTIONATION AND RELATED METHODS [J].
GIDDINGS, JC .
JOURNAL OF CHROMATOGRAPHY, 1987, 395 :19-32
[53]  
Grass B, 2002, J SEP SCI, V25, P135, DOI 10.1002/1615-9314(20020201)25:3&lt
[54]  
135::AID-JSSC135&gt
[55]  
3.0.CO
[56]  
2-
[57]   A new PMMA-microchip device for isotachophoresis with integrated conductivity detector [J].
Grass, B ;
Neyer, A ;
Jöhnck, M ;
Siepe, D ;
Eisenbeiss, F ;
Weber, G ;
Hergenröder, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (03) :249-258
[58]   Partial electroosmotic pumping in complex capillary systems -: Part 2:: Fabrication and application of a micro total analysis system (μTAS) suited for continuous volumetric nanotitrations [J].
Guenat, OT ;
Ghiglione, D ;
Morf, WE ;
de Rooij, NF .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (03) :273-282
[59]   Novel three-dimensional capillary electrophoresis system for complex and trace analysis [J].
Hanna, M ;
Simpson, C ;
Perrett, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 894 (1-2) :117-128
[60]   BIDIRECTIONAL ISOTACHOPHORESIS .1. VERIFICATION OF BIDIRECTIONAL ISOTACHOPHORESIS AND SIMULTANEOUS DETERMINATION OF ANIONIC AND CATIONIC COMPONENTS [J].
HIROKAWA, T ;
WATANABE, K ;
YOKOTA, Y ;
KISO, Y .
JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2) :251-259