A new PMMA-microchip device for isotachophoresis with integrated conductivity detector

被引:153
作者
Grass, B
Neyer, A
Jöhnck, M
Siepe, D
Eisenbeiss, F
Weber, G
Hergenröder, R
机构
[1] ISAS, Inst Spektrochem & Angew Spektroskopie, D-44013 Dortmund, Germany
[2] Univ Dortmund, D-44221 Dortmund, Germany
[3] MERCK KGaA, D-64293 Darmstadt, Germany
关键词
miniaturization; microchip; poly(methylmethacrylat); isotachophoresis; conductivity detection;
D O I
10.1016/S0925-4005(00)00643-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report describes the design, fabrication and use of new microanalytical devices based on polymer substrates for electrophoretic methods, especially isotachophoresis. The devices are fabricated by hot embossing and are sealed with a thin plexiglas cover plate which contains platinum electrodes for contact conductivity detection and power supply. Poly(methylmethacrylat) (PMMA) shows good prospects for the development of low-cost disposable or semi-disposable microanalytical devices. Two different chip-designs are introduced to demonstrate the advantages of the manufacturing procedure and the use of poly(methylmethacrylat) as substrate material. The channel system on the chips is equipped with two sample loops with different volumes to take advantage of the high sample loadability and the enrichment qualities of isotachophoresis. In addition, two separation columns allow two-dimensional on-column ITP-ITP- and CZE-ITP-coupling. Separations of organic acids are used to demonstrate the principle of the isotachophoresis-chips. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:249 / 258
页数:10
相关论文
共 55 条
[1]   Analysis of oligonucleotides by on-column transient capillary isotachophoresis and capillary electrophoresis in poly(ethylene glycol)-filled columns [J].
Auriola, S ;
Jaaskelainen, I ;
Regina, M ;
Urtti, A .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3907-3911
[2]   Enhancement of sample loadings for the analysis of oligosaccharides isolated from Pseudomonas aeruginosa using transient isotachophoresis and capillary zone electrophoresis-electrospray-mass spectrometry [J].
Auriola, S ;
Thibault, P ;
Sadovskaya, I ;
Altman, E .
ELECTROPHORESIS, 1998, 19 (15) :2665-2676
[3]  
BALDOCK SJ, MICROTOTAL ANAL SYST, P359
[4]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[5]  
2-7
[6]  
Becker H, 2000, MESA MG, P253
[7]  
Bocek P., 1988, ANAL ISOTACHOPHORESI
[8]   Micromachining sensors for electrochemical measurement in subnanoliter volumes [J].
Bratten, CDT ;
Cobbold, PH ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :253-258
[9]   Electrochemical analysis in picoliter microvials [J].
Clark, RA ;
Hietpas, PB ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :259-263
[10]   Capillary zone electrophoresis separations of enantiomers present in complex ionic matrices with on-line isotachophoretic sample pretreatment [J].
Danková, M ;
Kaniansky, D ;
Fanali, S ;
Iványi, F .
JOURNAL OF CHROMATOGRAPHY A, 1999, 838 (1-2) :31-43