A new PMMA-microchip device for isotachophoresis with integrated conductivity detector

被引:153
作者
Grass, B
Neyer, A
Jöhnck, M
Siepe, D
Eisenbeiss, F
Weber, G
Hergenröder, R
机构
[1] ISAS, Inst Spektrochem & Angew Spektroskopie, D-44013 Dortmund, Germany
[2] Univ Dortmund, D-44221 Dortmund, Germany
[3] MERCK KGaA, D-64293 Darmstadt, Germany
关键词
miniaturization; microchip; poly(methylmethacrylat); isotachophoresis; conductivity detection;
D O I
10.1016/S0925-4005(00)00643-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report describes the design, fabrication and use of new microanalytical devices based on polymer substrates for electrophoretic methods, especially isotachophoresis. The devices are fabricated by hot embossing and are sealed with a thin plexiglas cover plate which contains platinum electrodes for contact conductivity detection and power supply. Poly(methylmethacrylat) (PMMA) shows good prospects for the development of low-cost disposable or semi-disposable microanalytical devices. Two different chip-designs are introduced to demonstrate the advantages of the manufacturing procedure and the use of poly(methylmethacrylat) as substrate material. The channel system on the chips is equipped with two sample loops with different volumes to take advantage of the high sample loadability and the enrichment qualities of isotachophoresis. In addition, two separation columns allow two-dimensional on-column ITP-ITP- and CZE-ITP-coupling. Separations of organic acids are used to demonstrate the principle of the isotachophoresis-chips. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:249 / 258
页数:10
相关论文
共 55 条
[41]   Fabrication of plastic microfluid channels by imprinting methods [J].
Martynova, L ;
Locascio, LE ;
Gaitan, M ;
Kramer, GW ;
Christensen, RG ;
MacCrehan, WA .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4783-4789
[42]   Capillary electrophoresis and contactless conductivity detection of ions in narrow inner diameter capillaries [J].
Mayrhofer, K ;
Zemann, AJ ;
Schnell, E ;
Bonn, GK .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3828-3833
[43]   Microchannel electrophoretic separations of DNA in injection-molded plastic substrates [J].
McCormick, RM ;
Nelson, RJ ;
AlonsoAmigo, MG ;
Benvegnu, J ;
Hooper, HH .
ANALYTICAL CHEMISTRY, 1997, 69 (14) :2626-2630
[44]   New leading electrolyte for the direct determination of chloride and other anions in analytical isotachophoresis [J].
Meissner, T ;
Eisenbeiss, F ;
Jastorff, B .
JOURNAL OF CHROMATOGRAPHY A, 1999, 838 (1-2) :81-88
[45]   Determination of anionic trace impurities in acetic acid by two-dimensional capillary isotachophoresis [J].
Meissner, T ;
Eisenbeiss, F ;
Jastorff, B .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (05) :459-464
[46]   Determination of anionic trace impurities in glycerol by capillary isotachophoresis with enlarged sample load [J].
Meissner, T ;
Eisenbeiss, F ;
Jastorff, B .
JOURNAL OF CHROMATOGRAPHY A, 1998, 810 (1-2) :201-208
[47]   UV laser machined polymer substrates for the development of microdiagnostic systems [J].
Roberts, MA ;
Rossier, JS ;
Bercier, P ;
Girault, H .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2035-2042
[48]   Electrochemical detection in polymer microchannels [J].
Rossier, JS ;
Roberts, MA ;
Ferrigno, R ;
Girault, HH .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4294-4299
[49]   PLANAR GLASS CHIPS FOR CAPILLARY ELECTROPHORESIS - REPETITIVE SAMPLE INJECTION, QUANTITATION, AND SEPARATION EFFICIENCY [J].
SEILER, K ;
HARRISON, DJ ;
MANZ, A .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :1481-1488
[50]   ON-CHIP MICROBAND ARRAY ELECTROCHEMICAL DETECTOR FOR USE IN CAPILLARY ELECTROPHORESIS [J].
SLATER, JM ;
WATT, EJ .
ANALYST, 1994, 119 (11) :2303-2307