PLANAR GLASS CHIPS FOR CAPILLARY ELECTROPHORESIS - REPETITIVE SAMPLE INJECTION, QUANTITATION, AND SEPARATION EFFICIENCY

被引:234
作者
SEILER, K
HARRISON, DJ
MANZ, A
机构
[1] UNIV ALBERTA,DEPT CHEM,EDMONTON T6G 2G2,ALBERTA,CANADA
[2] CIBA GEIGY AG,CENT ANALYT RES,CH-4002 BASEL,SWITZERLAND
关键词
D O I
10.1021/ac00058a029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sample injection system and a capillary electrophoresis channel integrated together on a planar glass substrate are described, and the performance is evaluated. Voltages of at least 25 kV may be applied over an 11-cm-long capillary channel with sufficient dissipation of the Joule heat generated (1.8 W/m). The glass substrate sustains at least 10(5) V/cm dc without dielectric breakdown. Using laser-induced fluorescence detection, mixtures of fluorescein derivatives and fluorescein isothiocyanate-labeled amino acids were injected and separated. Up to 100 000 theoretical plates and approximately 20 plates/V were obtained under optimized conditions, comparable to results with fused-silica capillaries. Quantitative analysis showed that peak areas were proportional to the amount injected for injected plug lengths greater than 200 mum. The presence of two rectangular corners in a 0.85-cm-long separation channel did not increase dispersion detectably, indicating a serpentine capillary channel 0.5 m in length could be fabricated in less than a 1-cm2 area.
引用
收藏
页码:1481 / 1488
页数:8
相关论文
共 18 条
  • [1] [Anonymous], 1990, UOP Patents, Patent No. [US 4,908,122, 4908122]
  • [2] SUBATTOMOLE AMINO-ACID ANALYSIS BY CAPILLARY ZONE ELECTROPHORESIS AND LASER-INDUCED FLUORESCENCE
    CHENG, YF
    DOVICHI, NJ
    [J]. SCIENCE, 1988, 242 (4878) : 562 - 564
  • [3] PROBLEMS OF QUANTITATIVE INJECTION IN CAPILLARY ZONE ELECTROPHORESIS
    DOSE, EV
    GUIOCHON, G
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (02) : 123 - 128
  • [4] CAPILLARY ELECTROPHORESIS
    EWING, AG
    WALLINGFORD, RA
    OLEFIROWICZ, TM
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (04) : A292 - +
  • [5] GALE RJ, 1990, BIOSENSOR TECHNOLOGY, P55
  • [6] GROSMAN PD, 1992, CAPILLARY ELECTROPHO
  • [7] CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP
    HARRISON, DJ
    MANZ, A
    FAN, ZH
    LUDI, H
    WIDMER, HM
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1926 - 1932
  • [8] ANALYSIS OF FACTORS CAUSING PEAK BROADENING IN CAPILLARY ZONE ELECTROPHORESIS
    HUANG, XH
    COLEMAN, WF
    ZARE, RN
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 480 : 95 - 110
  • [9] BIAS IN QUANTITATIVE CAPILLARY ZONE ELECTROPHORESIS CAUSED BY ELECTROKINETIC SAMPLE INJECTION
    HUANG, XH
    GORDON, MJ
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (04) : 375 - 377
  • [10] ZONE ELECTROPHORESIS IN OPEN-TUBULAR GLASS-CAPILLARIES
    JORGENSON, JW
    LUKACS, KD
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (08) : 1298 - 1302