A JAVA']JAVA environment for medical image data analysis: initial application for brain PET quantitation

被引:164
作者
Mikolajczyk, K [1 ]
Szabatin, M
Rudnicki, P
Grodzki, M
Burger, C
机构
[1] Warsaw Univ Technol, Inst Precis & Biomed Engn, PL-00661 Warsaw, Poland
[2] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
来源
MEDICAL INFORMATICS | 1998年 / 23卷 / 03期
关键词
!text type='Java']Java[!/text; DICOM; functional imaging; positron emission tomography;
D O I
10.3109/14639239809001400
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Analysis software for medical image data tends to be expensive and usable only in a restricted environment. Therefore the aim of the current project was to implement a flexible framework for medical image processing and visualization which is portable among platforms and open to different data formats including DICOM 3.0. The software was designed as a set of tools which encapsulate specialized functionality. The tools are full stand alone applications, but they are also able to present a co-operating environment within which images and other information are communicated in real time. Currently, the emphasis is on quantitative analysis of PET data by kinetic modelling. However, general viewing capabilities are included, and the design is flexible enough that other types of processing can easily be integrated by simply plugging in Java classes. The software is successfully applied to PET data quantitation in clinical research studies and even patient studies. Portability was aimed at by encoding the programs in Java. Experience shows that the implementation of such a complex and computationally demanding Java application is feasible. Although there are major portability issues to consider, configurations can be found on which the software runs stably and at a speed comparable to C code if just-in-time compilation is available.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 10 条
  • [1] STRATEGY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING SHORT-LIVED TRACERS AND EMISSION TOMOGRAPHY
    ALPERT, NM
    ERIKSSON, L
    CHANG, JY
    BERGSTROM, M
    LITTON, JE
    CORREIA, JA
    BOHM, C
    ACKERMAN, RH
    TAVERAS, JM
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) : 28 - 34
  • [2] HERSCOVITCH P, 1983, J NUCL MED, V24, P782
  • [3] NON-INVASIVE DETERMINATION OF LOCAL CEREBRAL METABOLIC-RATE OF GLUCOSE IN MAN
    HUANG, SC
    PHELPS, ME
    HOFFMAN, EJ
    SIDERIS, K
    SELIN, CJ
    KUHL, DE
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (01): : E69 - E82
  • [4] Ichise M, 1996, J NUCL MED, V37, P513
  • [5] Ichise M, 1997, J NUCL MED, V38, P31
  • [6] MEYER E, 1989, J NUCL MED, V30, P1069
  • [7] GRAPHICAL EVALUATION OF BLOOD-TO-BRAIN TRANSFER CONSTANTS FROM MULTIPLE-TIME UPTAKE DATA
    PATLAK, CS
    BLASBERG, RG
    FENSTERMACHER, JD
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (01) : 1 - 7
  • [8] RAICHLE ME, 1983, J NUCL MED, V24, P790
  • [9] TALAIRACH J, 1988, C PLANAR STEREOTAXIC
  • [10] Noninvasive quantification of rCBF using positron emission tomography
    Watabe, H
    Itoh, M
    Cunningham, V
    Lammertsma, AA
    Bloomfield, P
    Mejia, M
    Fujiwara, T
    Jones, AKP
    Jones, T
    Nakamura, T
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (02) : 311 - 319