Indoor air quality at nine shopping malls in Hong Kong

被引:91
作者
Li, WM [1 ]
Lee, SC [1 ]
Chan, LY [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Res Ctr Urban Environm Technol & Management, Kowloon, Hong Kong, Peoples R China
关键词
shopping mall; indoor air quality; Hong Kong; carbon dioxide; carbon monoxide; particulate and total bacteria count;
D O I
10.1016/S0048-9697(00)00833-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hong Kong is one of the most attractive shopping paradises in the world. Many local people and international tourists favor to spend their time in shopping malls in Hong Kong. Good indoor air quality is, therefore, very essential to shoppers. In order to characterize the indoor air quality in shopping malls, nine shopping malls in Hong Kong were selected for this study. The indoor air pollutants included carbon dioxide (CO2), carbon monoxide (CO)(2) total hydrocarbons (THC), formaldehyde (HCHO), respirable particulate matter (PM10) and total bacteria count (TBC). More than 40% of the shopping malls had 1-h average CO2 levels above the 1000 ppm of the ASHRAE standard on both weekdays and weekends. Also, they had average weekday PM10 concentrations that exceeded the Hong Kong Indoor Air Quality Objective (HKIAQO). The highest indoor PM10 level at a mail was 380 mug/m(3). Of the malls surveyed, 30% had indoor airborne bacteria levels above 1000 cfu/m(3) set by the HKIAQO. The elevated indoor CO2 and bacteria levels could result from high occupancy combined with insufficient ventilation. The increased PM10, levels could be probably attributed to illegal smoking inside these establishments. In comparison, the shopping malls that contained internal public transport drop-off areas, where vehicles were parked with idling engines and had major entry doors close to heavy traffic roads had higher CO and PM10, indoor levels. In addition, the extensive use of cooking stoves without adequate ventilation inside food courts could increase indoor CO2, CO and PM10 levels. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:27 / 40
页数:14
相关论文
共 26 条
[11]   Tourism shopping and its contributions to Hong Kong [J].
Heung, VCS ;
Qu, HL .
TOURISM MANAGEMENT, 1998, 19 (04) :383-386
[12]   Indoor air quality and health [J].
Jones, AP .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (28) :4535-4564
[13]  
Lam GCK, 1999, ATMOS ENVIRON, V33, P1
[14]  
Lee DH, 1999, CHEM ENG TECHNOL, V22, P443, DOI 10.1002/(SICI)1521-4125(199905)22:5<443::AID-CEAT443>3.0.CO
[15]  
2-L
[16]   Comparison of indoor and outdoor air quality at two staff quarters in Hong Kong [J].
Lee, SC .
ENVIRONMENT INTERNATIONAL, 1997, 23 (06) :791-797
[17]  
LEE SJ, 1994, J VAC SCI TECHNOL, V12, P1
[18]   FACTORS INFLUENCING INDOOR AIR-QUALITY IN HONG-KONG - MEASUREMENTS IN OFFICES AND SHOPS [J].
LIAO, SST ;
BACONSHONE, J ;
KIM, YS .
ENVIRONMENTAL TECHNOLOGY, 1991, 12 (09) :737-745
[19]  
Maroni M., 1995, Indoor Air Quality: A Comprehensive Reference Book
[20]  
MOLHAVE L, 1987, INDOOR AIR 87, V2, P469