The KneeKG system: a review of the literature

被引:65
作者
Lustig, Sebastien [1 ,2 ]
Magnussen, Robert A. [3 ]
Cheze, Laurence [2 ]
Neyret, Philippe [1 ,2 ]
机构
[1] Hop Croix Rousse, Dept Orthopaed Surg, Ctr Albert Trillat, F-69004 Lyon, France
[2] Univ Lyon 1, Lab Biomecan & Mecan Chocs, UMR T9406, IFSTTAR, F-69622 Lyon, France
[3] Ohio State Univ, Sch Med, Dept Orthopaed Surg, Columbus, OH 43210 USA
关键词
Knee; Movement analysis; KneeKG; Rotational laxity; PIVOT SHIFT PHENOMENON; CRUCIATE LIGAMENT INJURY; TREADMILL WALKING; JOINT KINEMATICS; GAIT; ARTHROMETER; KT-1000; OSTEOARTHRITIS; INSTABILITY; ROLIMETER;
D O I
10.1007/s00167-011-1867-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Purpose Accurately quantifying knee joint motion is not simple. Skin movement over the medial and lateral femoral condyles is the greatest obstacle to obtaining accurate movement data non-invasively. The KneeKG (TM) system was developed with the objective of providing high reliability movement analysis. The goal of this manuscript is to review the technical details, clinical evidence, and potential applications of this system for evaluation of rotational knee laxity. Methods A comprehensive review of the MEDLINE database was carried out to identify all clinical and biomechanical studies related to KneeKG (TM) system. Results The KneeKG (TM) system non-invasively quantifies knee abduction/adduction, axial rotation, and relative translation of the tibia and femur. The accuracy and reproducibility of the system have been assessed. The average accuracy of the acquisition is 0.4 degrees for abduction/adduction, 2.3 degrees for axial rotation, 2.4 mm for anteroposterior translation, and 1.1 mm for axial translation. This clinical tool enables an accurate and objective assessment of the tri-planar function of the knee joint. The measured biomechanical parameters are sensitive to changes in gait due to knee osteoarthritis and ACL deficiency. Conclusion The KneeKG (TM) system provides reliable movement analysis. This system has the potential to improve understanding the biomechanical consequences of trauma or degenerative changes of the knee as well as more accurately quantify rotational laxity as detected by a positive pivot-shift test.
引用
收藏
页码:633 / 638
页数:6
相关论文
共 35 条
[1]
Arneja S, 2009, J Orthop Surg (Hong Kong), V17, P77
[2]
Evaluation of anterior knee joint instability with the Rolimeter - A test in comparison with manual assessment and measuring with the KT-1000 arthrometer [J].
Balasch, H ;
Schiller, M ;
Friebel, H ;
Hoffmann, F .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (04) :204-208
[3]
Rotational laxity greater in patients with contralateral anterior cruciate ligament injury than healthy volunteers [J].
Branch, T. P. ;
Browne, J. E. ;
Campbell, J. D. ;
Siebold, R. ;
Freedberg, H. I. ;
Arendt, E. A. ;
Lavoie, F. ;
Neyret, P. ;
Jacobs, Cale A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (10) :1379-1384
[4]
Fuentes AHHI, 2007, CLIN J SPORT MED, V17, P165
[5]
Gait adaptation in chronic anterior cruciate ligament-deficient patients: Pivot-shift avoidance gait [J].
Fuentes, Alexandre ;
Hagemeister, Nicola ;
Ranger, Pierre ;
Heron, Timothy ;
de Guise, Jacques A. .
CLINICAL BIOMECHANICS, 2011, 26 (02) :181-187
[6]
Three-dimensional knee analyzer validation by simple fluoroscopic study [J].
Ganjikia, S ;
Duval, N ;
Yahia, L ;
de Guise, J .
KNEE, 2000, 7 (04) :221-231
[7]
The Rolimeter: a new arthrometer compared with the KT-1000 [J].
Ganko, A ;
Engebretsen, L ;
Ozer, H .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2000, 8 (01) :36-39
[8]
A functional evaluation of prosthetic foot kinematics during lower-limb amputee gait [J].
Goujon, H. ;
Bonnet, X. ;
Sautreuil, P. ;
Maurisset, M. ;
Darmon, L. ;
Fode, P. ;
Lavaste, F. .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2006, 30 (02) :213-223
[9]
A reproducible method for studying three-dimensional knee kinematics [J].
Hagemeister, N ;
Parent, G ;
Van de Putte, M ;
St-Onge, N ;
Duval, N ;
de Guise, J .
JOURNAL OF BIOMECHANICS, 2005, 38 (09) :1926-1931
[10]
In vivo reproducibility of a new non-invasive diagnostic tool for three-dimensional knee evaluation [J].
Hagemeister, N ;
Yahia, LH ;
Duval, N ;
de Guise, JA .
KNEE, 1999, 6 (03) :175-181