AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology

被引:605
作者
Ma, CM [1 ]
Coffey, CW
DeWerd, LA
Liu, C
Nath, R
Seltzer, SM
Seuntjens, JP
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Natl Res Council Canada, Ionizing Radiat Stand, Ottawa, ON K1A 0R6, Canada
[3] Vanderbilt Univ, Med Ctr, Dept Radiat Oncol, Nashville, TN 37232 USA
[4] Univ Wisconsin, Madison, WI 53706 USA
[5] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
[6] Yale Univ, Sch Med, Dept Therapeut Radiol, New Haven, CT 06510 USA
[7] Natl Inst Stand & Technol, Ionizing Radiat Div, Gaithersburg, MD 20899 USA
[8] McGill Univ, Montreal Gen Hosp, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
关键词
low- and medium-energy x rays; dosimetry protocol; calibration; ionization chambers; reference dosimetry; relative dosimetry;
D O I
10.1118/1.1374247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The American Association of Physicists in Medicine (AAPM) presents a new protocol, developed by the Radiation Therapy Committee Task Group 61, fur reference dosimetry of low- and medium-energy x rays for radiotherapy and radiobiology (40kV less than or equal to tube potential less than or equal to 300 kV). It is based on ionization chambers calibrated in air in terms of air kerma. If the point of interest is at or close to the surface, one unified approach over the entire energy range shall be used to determine absorbed dose to water at the surface of a water phantom based on an in-air measurement (the "in-air" method), If the point of interest is at a depth, an in-water measurement at a depth of 2 cm shall be used for tube potentials greater than or equal to 100 kV (the "in-phantom'' method). The in-phantom method is not recommended for tube potentials <100 kV. Guidelines are provided to determine the close at other points in water and the dose at the surface of other biological materials of interest. The protocol is based on an up-to-date data set of basic dosimetry parameters, which product: consistent dose values for the two methods recommended, Estimates of uncertainties on the final dose values are also presented. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:868 / 893
页数:26
相关论文
共 78 条
[1]  
Aldrich J E, 1992, Med Dosim, V17, P69
[2]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[4]  
[Anonymous], P IAEA INT S MEAS AS
[5]  
[Anonymous], 1987, RAD DOSIMETRY
[6]  
Attix FH., 1986, INTRO RADIOLOGICAL P, P358
[7]   Performance characteristics of the Pantak DXT-300 kilovoltage X-ray treatment machine [J].
Aukett, RJ ;
Thomas, DW ;
Seaby, AW ;
Gittins, JT .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (824) :726-734
[8]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[9]  
Boag J, 1966, RADIATION DOSIMETRY, V2, P1
[10]   GENERAL RECOMBINATION IN IONIZATION CHAMBERS WITH SPATIALLY NONUNIFORM IONIZATION INTENSITY - 2 SPECIAL CASES [J].
BOAG, JW .
INTERNATIONAL JOURNAL FOR RADIATION PHYSICS AND CHEMISTRY, 1975, 7 (2-3) :243-249