Conformal radiotherapy (CRT) planning for lung cancer: Analysis of intrathoracic organ motion during extreme phases of breathing

被引:125
作者
Giraud, P
De Rycke, Y
Dubray, B
Helfre, S
Voican, D
Guo, L
Rosenwald, JC
Keraudy, K
Housset, M
Touboul, E
Cosset, JM
机构
[1] Inst Curie, Dept Oncol Radiotherapie, F-75248 Paris 05, France
[2] Inst Curie, Dept Radiat Oncol, F-75248 Paris, France
[3] Inst Curie, Dept Biostat, F-75248 Paris 05, France
[4] Tenon Hosp, Dept Radiat Oncol, Paris, France
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 51卷 / 04期
关键词
three-dimensional conformal radiotherapy; computed tomography; organ motion; lung cancer;
D O I
10.1016/S0360-3016(01)01766-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Conformal radiotherapy beams are defined on the basis of static computed tomography acquisitions by taking into account setup errors and organ/tumor motion during breathing. In the absence of precise data, the size of the margins is estimated arbitrarily. The objective of this study was to evaluate the amplitude of maximum intrathoracic organ motion during breathing. Methods and Materials: Twenty patients treated for non-small-cell lung cancer were included in the study: 10 patients at the Institut Curie with a personalized alpha cradle immobilization and 10 patients at Tenon Hospital with just the Posirest device below their arms. Three computed tomography acquisitions were performed in the treatment position: the first during free breathing and the other two during deep breath-hold inspiration and expiration. For each acquisition, the displacements of the various intrathoracic structures were measured in three dimensions. Results: Patients from the two centers were comparable in terms of age, weight, height, tumor site, and stage. In the overall population, the greatest displacements were observed for the diaphragm, and the smallest displacements were observed for the lung apices and carina. The relative amplitude of motion was comparable between the two centers. The use of a personalized immobilization device reduced lateral thoracic movements (p < 0.02) and lung apex movements (p < 0.02). Conclusion: Intrathoracic organ movements during extreme phases of breathing are considerable. Quantification of organ motion is necessary for definition of the safety margins. A personalized immobilization device appears to effectively reduce apical and lateral displacement. <(c)> 2001 Elsevier Science Inc.
引用
收藏
页码:1081 / 1092
页数:12
相关论文
共 26 条
[11]   Influence of respiration on calculation and delivery of the prescribed dose in external radiotherapy [J].
Jacobs, I ;
Vanregemorter, J ;
Scalliet, P .
RADIOTHERAPY AND ONCOLOGY, 1996, 39 (02) :123-128
[12]   REPRODUCIBILITY OF QUANTITATIVE, SPIROMETRICALLY CONTROLLED CT [J].
KOHZ, P ;
STABLER, A ;
BEINERT, T ;
BEHR, J ;
EGGE, T ;
HEUCK, A ;
REISER, MF .
RADIOLOGY, 1995, 197 (02) :539-542
[13]   Respiration gated radiotherapy treatment: A technical study [J].
Kubo, HD ;
Hill, BC .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) :83-91
[14]   Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center [J].
Kubo, HD ;
Len, PM ;
Minohara, S ;
Mostafavi, H .
MEDICAL PHYSICS, 2000, 27 (02) :346-353
[15]  
Kutcher, 1995, Semin Radiat Oncol, V5, P134, DOI 10.1016/S1053-4296(95)80006-9
[16]  
Lehmann E. L., 1975, NONPARAMETRICS STAT
[17]   ACCURATE CONTIGUOUS SECTIONS WITHOUT BREATH-HOLDING ON CHEST CT - VALUE OF RESPIRATORY GATING AND ULTRAFAST CT [J].
MORI, M ;
MURATA, K ;
TAKAHASHI, M ;
SHIMOYAMA, K ;
OTA, T ;
MORITA, R ;
SAKAMOTO, T .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (05) :1057-1062
[18]  
Munro, 1995, Semin Radiat Oncol, V5, P115, DOI 10.1016/S1053-4296(95)80005-0
[19]  
Noel G, 1997, Cancer Radiother, V1, P249, DOI 10.1016/S1278-3218(97)89772-7
[20]   ACCURACY OF RADIATION-FIELD ALIGNMENT IN CLINICAL-PRACTICE [J].
RABINOWITZ, I ;
BROOMBERG, J ;
GOITEIN, M ;
MCCARTHY, K ;
LEONG, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (10) :1857-1867