Coupling continuous flow systems to instruments based on discrete sample introduction

被引:13
作者
Valcarcel, M [1 ]
Gallego, M [1 ]
Rios, A [1 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14004 Cordoba, Spain
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1998年 / 362卷 / 01期
关键词
D O I
10.1007/s002160051035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The interfaces between low-pressure continuous sample treatment systems and high-level information instruments such as gas chromatographs, capillary electrophoresis equipment and graphite furnace atomic spectroscopic instruments, which are characterized by conventional discrete sample introduction devices, are presented. The present and future developments are discussed of (directly) linking real samples and those analytical equipments with the main objective of avoiding or minimizing manually implemented preliminary operations of the analytical process.
引用
收藏
页码:58 / 66
页数:9
相关论文
共 81 条
[51]   HY-PHEN-ATED METHODS [J].
HIRSCHFELD, T .
ANALYTICAL CHEMISTRY, 1980, 52 (02) :A297-&
[52]   New interface for coupling flow-injection and capillary electrophoresis [J].
Kuban, P ;
Engstrom, A ;
Olsson, JC ;
Thorsen, G ;
Tryzell, R ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1997, 337 (02) :117-124
[53]   On-line dialysis coupled to a capillary electrophoresis system for determination of small anions [J].
Kuban, P ;
Karlberg, B .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1169-1173
[54]   TRANSVERSE FLOW GATING INTERFACE FOR THE COUPLING OF MICROCOLUMN-LC WITH CZE IN A COMPREHENSIVE 2-DIMENSIONAL SYSTEM [J].
LEMMO, AV ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1576-1581
[55]  
Li S. F. Y., 1993, CAPILLARY ELECTROPHO
[56]   SELECTIVE FLOW-INJECTION SORBENT EXTRACTION FOR DETERMINATION OF CADMIUM, COPPER AND LEAD IN BIOLOGICAL AND ENVIRONMENTAL-SAMPLES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
MA, RL ;
VANMOL, W ;
ADAMS, F .
ANALYTICA CHIMICA ACTA, 1994, 293 (03) :251-260
[57]   DETERMINATION OF ULTRA-TRACE LEVELS OF METAL-IONS IN SEA-WATER WITH ONLINE PRECONCENTRATION AND ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
PORTA, V ;
ABOLLINO, O ;
MENTASTI, E ;
SARZANINI, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :119-122
[58]   AUTOMATED MONITORING OF ORGANIC TRACE COMPONENTS IN WATER .1. CONTINUOUS-FLOW EXTRACTION TOGETHER WITH ONLINE CAPILLARY GAS-CHROMATOGRAPHY [J].
ROERAADE, J .
JOURNAL OF CHROMATOGRAPHY, 1985, 330 (02) :263-274
[59]  
Ruzicka Jaromir., 1988, FLOW INJECTION ANAL, V2nd
[60]   AUTOMATED GAS-CHROMATOGRAPH MASS-SPECTROMETER FOR ROUTINE ATMOSPHERIC FIELD-MEASUREMENTS OF THE CFC REPLACEMENT COMPOUNDS, THE HYDROFLUOROCARBONS AND HYDROCHLOROFLUOROCARBONS [J].
SIMMONDS, PG ;
ODOHERTY, S ;
NICKLESS, G ;
STURROCK, GA ;
SWABY, R ;
KNIGHT, P ;
RICKETTS, J ;
WOFFENDIN, G ;
SMITH, R .
ANALYTICAL CHEMISTRY, 1995, 67 (04) :717-723