The feasibility of spatial high-resolution magnetic resonance angiography (MRA) of the renal arteries at 3.0 T

被引:29
作者
Michaely, HJ [1 ]
Nael, K [1 ]
Schoenberg, S [1 ]
Finn, JP [1 ]
Laub, G [1 ]
Reiser, MF [1 ]
Ruehm, SG [1 ]
机构
[1] Univ Munich, Inst Klin Radiol, D-81377 Munich, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2005年 / 177卷 / 06期
关键词
MR-angiography; renal angiography; MR; high field strength imaging; high resolution; kidney;
D O I
10.1055/s-2005-858175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of high-spatial resolution magnetic resonance angiography (MRA) of the renal arteries at 3.0 T. Material and Methods: Twelve healthy volunteers (mean age, 38.8 years) underwent renal MRA at 3.0 T. The application of parallel imaging with an acceleration factor of 3 allowed obtaining MR angiographic data with a voxel size of 0.9 x 0.8 x 0.9 mm in scan time of only 16 s. A dose of 0.2 mmol/kg body weight of 0.5-molar gadodiamide was administered at a flow rate of 2 ml/s. For image analysis, image quality, presence of artifacts, venous contamination and level of noise were rated by two radiologists in consensus. Results: All examinations were of diagnostic quality. The image quality was rated good or very good in 91% (11/12) of cases. Due to the high parallel imaging factor the level of noise was slightly increased without diagnostic impairment. Mild venous enhancement was found in 75% (9/12) of the examinations. Conclusion: Renal MRA at 3.0 T is feasible with high spatial resolution and a short acquisition time.
引用
收藏
页码:800 / 804
页数:5
相关论文
共 16 条
[1]  
Campeau N G, 2001, Top Magn Reson Imaging, V12, P183, DOI 10.1097/00002142-200106000-00005
[2]  
Chen Q, 2004, RADIOLOGY, V231, P893, DOI [10.1148/radiol.2313021113, 10.1148/radio1:2313021113]
[3]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[4]   Intraindividual comparison of gadopentetate dimeglumine, gadobenate dimeglumine, and gadobutrol for pelvic 3D magnetic resonance angiography [J].
Herborn, CU ;
Lauenstein, TC ;
Ruehm, SG ;
Bosk, S ;
Debatin, JF ;
Goyen, M .
INVESTIGATIVE RADIOLOGY, 2003, 38 (01) :27-33
[5]   Limits to the accuracy of vessel diameter measurement in MR angiography [J].
Hoogeveen, RM ;
Bakker, CJG ;
Viergever, MA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06) :1228-1235
[6]  
Lin W, 2003, MAGN RESON IMAGING C, V11, pvi
[7]  
Lin Weili, 2003, Magn Reson Imaging Clin N Am, V11, P615, DOI 10.1016/S1064-9689(03)00068-0
[8]  
Schmitt F, 2004, RADIOLOGE, V44, P31, DOI 10.1007/s00117-003-1000-x
[9]  
SCHOENBERG SO, 2005, IN PRESS RADIOLOGY
[10]   Magnetic resonance angiography for the diagnosis of renal artery stenosis: A meta-analysis [J].
Tan, KT ;
Van Beek, EJR ;
Brown, PWG ;
Van Delden, OM ;
Tijssen, J ;
Ramsay, LE .
CLINICAL RADIOLOGY, 2002, 57 (07) :617-624