The influence of tibial slope on maximal flexion after total knee arthroplasty

被引:218
作者
Bellemans, J
Robijns, F
Duerinckx, J
Banks, S
Vandenneucker, H
机构
[1] Katholieke Univ Leuven, Univ Hosp Pellenberg, Dept Orthopaed Surg, B-3012 Pellenberg, Belgium
[2] Orthopaed Res Lab, W Palm Beach, FL USA
关键词
flexion; knee arthroplasty; tibial slope;
D O I
10.1007/s00167-004-0557-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Many surgeons believe that increasing the tibial slope in total knee arthroplasty (TKA) is beneficial with regard to maximal postoperative flexion. Review of the clinical literature, however, does not confirm this hypothesis, neither does it give an answer to the question of how much flexion gain can be expected per degree extra tibial slope. The purpose of this study was, therefore, to evaluate and quantify the influence of tibial slope on maximal postoperative flexion in contemporary posterior cruciate ligament (PCL)-retaining TKA. Twenty-one cadaver simulations of a standard PCL-retaining TKA were studied while reproducing identical deep flexion femorotibial kinematics as documented by three-dimensional computer-aided videofluoroscopy from patients with well-functioning TKAs of the same design. In each knee the tibial component was consecutively implanted with 0 degrees posterior slope, 4 degrees posterior slope, and 7 degrees posterior slope. Maximal flexion was recorded for each configuration. Average maximal flexion at 0 degrees tibial slope was 104 degrees, and increased significantly to 112 degrees when the same knees were implanted with 4 degrees tibial slope. Increasing the slope further to 7 degrees again significantly improved average maximal flexion to 120 degrees. When postoperative radiographic tibial slope was compared to maximal flexion, an average gain of 1.7 degrees flexion for every degree extra tibial slope was noted. Increasing the tibial slope in PCL-retaining TKA does indeed improve maximal flexion before tibial insert impingement occurs against the femoral bone. The surgeon can expect an average gain of 1.7 degrees flexion for every degree extra tibial slope.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 21 条
[1]
The bisurface total knee replacement: A unique design for flexion - Four-to-nine-year follow-up study [J].
Akagi, M ;
Nakamura, T ;
Matsusue, Y ;
Ueo, T ;
Nishijyo, K ;
Ohnishi, E .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (11) :1626-1633
[2]
Akagi Masao, 1997, Bulletin Hospital for Joint Diseases, V56, P225
[3]
Anouchi YS, 1996, CLIN ORTHOP RELAT R, P87
[4]
Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[5]
In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[6]
Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset [J].
Bellemans, J ;
Banks, S ;
Victor, J ;
Vandenneucker, H ;
Moemans, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :50-53
[7]
In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty [J].
Bertin, KC ;
Komistek, RD ;
Dennis, DA ;
Hoff, WA ;
Anderson, DT ;
Langer, T .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1040-1048
[8]
BONNIN M, 1990, ETUDE CLIN BIOMECHAN, V180
[9]
Dennis DA, 1998, CLIN ORTHOP RELAT R, P47
[10]
JORDAN LR, 1995, CLIN ORTHOP RELAT R, P231