Methacrylate monolithic columns for capillary liquid chromatography polymerized using ammonium peroxodisulfate as initiator

被引:49
作者
Holdsvendová, P
Coufal, P
Suchánková, J
Tesarová, E
Bosáková, Z
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Sci, CR-12840 Prague 2, Czech Republic
[2] Charles Univ Prague, Dept Phys & Macromol Chem, Fac Sci, CR-12840 Prague 2, Czech Republic
关键词
monoliths; methacrylate; stationary phases; CLC; chemical initiation;
D O I
10.1002/jssc.200301564
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four methacrylate ester-based monolithic columns for capillary liquid chromatography (CLC) were prepared by radical polymerization with ammonium peroxodisulfate (3 columns) and by thermal initiation (1 column). The polymerization mixture consisted of butyl methacrylate (BMA) and ethylene glycol dimethacrylate (EDMA), propan-1-ol, butane-1,4-diol, water, and ammonium peroxodisulfate as initiator. It was necessary to add N,N,N',N'-tetramethylethylenediamine (TEMED) to the polymerization mixture to activate the reaction. The amount of initiator and activator was optimized to attain quantitative polymerization. The reproducibility of three columns prepared at ambient temperature was studied. The most efficient column with HETP of 29 mum for uracil was compared to the monolithic column prepared by thermal initiation with alpha,alpha'-azobisisobutyronitrile (AIBN). The efficiencies of all the test columns were characterized by van Deemter curves. Their total porosities were calculated from the retention time of uracil. Walters indices of hydrophobicity (HI) were calculated from the retention factors of anthracene and benzene. The columns prepared by both methods are comparable in their selectivities and efficiencies. They show the same characteristics because their total porosities and Walters. indices of hydrophobicity are consistent. However, the preparation of monoliths using ammonium peroxodisulfate was less demanding, because polymerization was possible at ambient temperature.
引用
收藏
页码:1623 / 1628
页数:6
相关论文
共 40 条
[1]   Modified capillary electrophoresis system for peptide, protein and double-stranded DNA analysis [J].
Belenkii, BG ;
Kassalainen, GE ;
Nasledov, DG .
JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (02) :189-196
[2]  
Bosáková Z, 2001, CHEM LISTY, V95, P569
[3]   ON THE PH-DEPENDENCE OF POLYMERIZATION EFFICIENCY, AS INVESTIGATED BY CAPILLARY ZONE ELECTROPHORESIS [J].
CAGLIO, S ;
RIGHETTI, PG .
ELECTROPHORESIS, 1993, 14 (5-6) :554-558
[4]   Instrumental requirements for nanoscale liquid chromatography [J].
Chervet, JP ;
Ursem, M ;
Salzmann, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1507-1512
[5]   Novel monolithic columns with templated porosity [J].
Chirica, GS ;
Remcho, VT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :223-232
[6]   Methacrylate monolithic columns of 320 μm ID for capillary liquid chromatography [J].
Coufal, P ;
Cihák, M ;
Suchánková, J ;
Tesarová, E ;
Bosáková, Z ;
Stulík, K .
JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) :99-106
[7]   Quantification and purity determination of newly synthesized thioacridines by capillary liquid chromatography [J].
Coufal, P ;
Bosáková, Z ;
Tesarová, E ;
Kafková, B ;
Suchánková, J ;
Barbe, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 770 (1-2) :183-189
[8]  
Coufal P, 2001, CHEM LISTY, V95, P509
[9]   Preparation of continuous beds for electrochromatography and reversed-phase liquid chromatography of low-molecular-mass compounds [J].
Ericson, C ;
Liao, JL ;
Nakazato, K ;
Hjerten, S .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :33-41
[10]  
FENG XD, 1988, MAKROMOL CHEM, V189, P77