Quantitative assessment of blood inflow effects in functional MRI signals

被引:70
作者
Gao, JH
Miller, I
Lai, S
Xiong, TJ
Fox, PT
机构
[1] USAF,BIOMED SCI CORPS,ST LOUIS,MO
[2] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,ST LOUIS,MO 63110
关键词
functional MRI (fMRI); flow; gradient-echo sequence; EPI;
D O I
10.1002/mrm.1910360219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Functional MRI (fMRI) signal dependence on changes in blood flow velocities were analyzed for both conventional and echo-planar (EPI) gradient-echo pulse sequences. As the flow velocity increases, the fMRI signal increases monotonically in spoiled gradient-echo sequences, while the fMRI signal may increase or decrease in conventional refocused gradient-echo sequences. A larger flip angle generates a larger inflow contribution to the fMRI signal. For conventional gradient-echo sequences, the inflow contribution to the fMRI images is dominated by the cortical draining veins, while its effect on capillaries is generally small and may be negligible in the spoiled sequences. For EPI gradient-echo sequences, the contribution from inflow effects is relatively small, as compared with the blood oxygen level-dependent (BOLD) contribution, to the fMRI signal, not only for capillaries but also for the cortical draining veins.
引用
收藏
页码:314 / 319
页数:6
相关论文
共 36 条
[1]   BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING [J].
AXEL, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1157-1166
[2]   TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION [J].
BANDETTINI, PA ;
WONG, EC ;
HINKS, RS ;
TIKOFSKY, RS ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :390-397
[3]   FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING [J].
BELLIVEAU, JW ;
KENNEDY, DN ;
MCKINSTRY, RC ;
BUCHBINDER, BR ;
WEISSKOFF, RM ;
COHEN, MS ;
VEVEA, JM ;
BRADY, TJ ;
ROSEN, BR .
SCIENCE, 1991, 254 (5032) :716-719
[4]   DYNAMIC MAPPING OF THE HUMAN VISUAL-CORTEX BY HIGH-SPEED MAGNETIC-RESONANCE-IMAGING [J].
BLAMIRE, AM ;
OGAWA, S ;
UGURBIL, K ;
ROTHMAN, D ;
MCCARTHY, G ;
ELLERMANN, JM ;
HYDER, F ;
RATTNER, Z ;
SHULMAN, RG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (22) :11069-11073
[5]   FUNCTIONAL NMR IMAGING USING FAST SPIN-ECHO AT 1.5 T [J].
CONSTABLE, RT ;
KENNAN, RP ;
PUCE, A ;
MCCARTHY, G ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :686-690
[6]   FUNCTIONAL BRAIN IMAGING AT 1.5-T USING CONVENTIONAL GRADIENT-ECHO MR-IMAGING TECHNIQUES [J].
CONSTABLE, RT ;
MCCARTHY, G ;
ALLISON, T ;
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :451-459
[7]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[8]   INFLOW VERSUS DEOXYHEMOGLOBIN EFFECTS IN BOLD FUNCTIONAL MRI USING GRADIENT ECHOES AT 1.5 T [J].
DUYN, JH ;
MOONEN, CTW ;
VANYPEREN, GH ;
DEBOER, RW ;
LUYTEN, PR .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :83-88
[9]   QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY [J].
EDELMAN, RR ;
SIEWERT, B ;
DARBY, DG ;
THANGARAJ, V ;
NOBRE, AC ;
MESULAM, MM ;
WARACH, S .
RADIOLOGY, 1994, 192 (02) :513-520
[10]   DYNAMIC MR IMAGING OF HUMAN BRAIN OXYGENATION DURING REST AND PHOTIC-STIMULATION [J].
FRAHM, J ;
BRUHN, H ;
MERBOLDT, KD ;
HANICKE, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05) :501-505